Blog
  • Some frequently asked questions for Batteries-Part 1

    Some frequently asked questions for Batteries-Part 1

    Dec , 31 2021
    From our long experience of providing battery solutions to our customers and partners, we have seen that there are some basic questions that are always asked. Here we are sharing some of the common questions and their answers regarding the batteries for your convenience. How long will it take before my battery is discharged? This depends on its capacity and the amount of power consumed by the conn...
    more
  • Determining the lifespan of a battery

    Determining the lifespan of a battery

    Dec , 31 2021
    The lifespan of a battery will vary considerably with how it is used, how it is maintained and charged, the temperature and other factors. Also the type of battery will determine its lifespan. 12 Volt Gel or AGM batteries If kept in a charged state when unused, the common lifespan of a 12-volt Gel or AGM battery is up to six years. After five or six years of float voltage at an average ambient tem...
    more
  • Seven good reason for installing a Battery monitoring system

    Seven good reason for installing a Battery monitoring system

    Dec , 17 2021
    A battery management system allows users to monitor individual cells within a battery pack. As cells work together to release energy to the load, it is crucial to maintain stability throughout the whole pack. This is where a battery management system (BMS) comes into play. A BMS allows for constant monitoring, gathering, and communicating information to an external interface where users can observ...
    more
  • Suitability of competing charging solutions in Genset applications

    Suitability of competing charging solutions in Genset applications

    Dec , 10 2021
    Instead of polyethylene, AGM type SLI batteries typically employ separators made of fiberglass. Because fiberglass does not oxidize like organic polyethylene, float charging at the battery manufacturer’s recommended float voltage is not inherently harmful to AGM type SLI batteries. Therefore, the intermittent charging method discussed is unlikely to increase the life of AGM type batteries. The dif...
    more
  • How a new intermittent charging algorithm addresses premature SLI battery failure?

    How a new intermittent charging algorithm addresses premature SLI battery failure?

    Dec , 06 2021
    A new charging algorithm addresses the problems of short genset battery life and sudden battery failure discussed above, while meeting the regulatory needs to deliver non-stop DC power to critical applications. The principle is simple and straightforward. Emulate the beneficial intermittent vehicle charging regime for which SLI batteries were originally designed, but continue charger operation to ...
    more
  • Why flooded SLI batteries in GENSET applications fail sooner and more suddenly than in vehicle applications?

    Why flooded SLI batteries in GENSET applications fail sooner and more suddenly than in vehicle applications?

    Dec , 06 2021
    Continuous float charging flooded SLI batteries accelerates the deterioration of polyethylene plate separators to a life shorter than that which battery designers intended. When subjected to continuous float charging, the dominant and earliest failure mode tends to be premature failure of the polyethylene separator. Separator failure typically results in short circuits that prevent the battery fro...
    more
  • Why flooded SLI batteries in GENSET applications fail sooner and more suddenly than in vehicle applications?

    Why flooded SLI batteries in GENSET applications fail sooner and more suddenly than in vehicle applications?

    Dec , 06 2021
    Even though the batteries perform the identical job of delivering high-rates of current to crank internal combustion engines, the “use model” of batteries employed in gensets is different in one key respect from those employed in vehicles. Batteries used on gensets are charged around the clock, whereas vehicle batteries are charged only intermittently. Flooded SLI batteries used in genset applicat...
    more
  • Why Boost Charging is Necessary?

    Why Boost Charging is Necessary?

    Dec , 06 2021
    Boost charging is a very necessary activity during the operation of a VRLA battery in their life time. In this article we are going to discuss about the necessity of Boost charging in details. The following example helps illustrate two facts about reducing battery recharge time: Cutting recharge time in half is more complex than using a charger that delivers twice as many amperes. Multi‐rate charg...
    more
  • What is Dynamic Boost and how does it works?

    What is Dynamic Boost and how does it works?

    Dec , 03 2021
    As with the current‐controlled automatic boost system, Dynamic Boost includes no pre‐programmed boost timer. Unlike the current‐controlled automatic boost system, however, Dynamic Boost automatically adjusts boost duration to take into account differing parasitic DC loads and other variables discussed above. The principle behind Dynamic Boost is simple and straightforward. Refer back to Figure 1. ...
    more
first page << 1 ... 3 4 5 6 7 8 9 10 >> last page

a total of10 pages

Are you looking for more information about EverExceed's  professional products and solutions?  Our expert team is always here to help. Please fill in the form and our sales representative will contact you shortly. EverExceed | Empower, Energize, Exceed the Energy you Expect forever.
copyright © 2024 EverExceed Industrial Co., Ltd.all rights reserved.
leave a message
welcome to everexceed
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

home

products

about

contact