Blog
  • Explanation of terms related to UPS power supply

    Explanation of terms related to UPS power supply

    Jul , 06 2024
    Transient Recovery Time: The time it takes for the output voltage to return to the specified range when there is a sudden change in load (0‐100%, 100%‐0), usually on the order of seconds (ms). Filter: a device used to eliminate noise, the input or output filtered to obtain a pure contention of the alternating current. Shielding: The use of physical principles, used to isolate the electromagnetic r...
    more
  • The characteristics and principle analysis of internal resistance of lithium battery

    The characteristics and principle analysis of internal resistance of lithium battery

    Jul , 12 2024
    The internal resistance of the battery is one of the most important characteristic parameters of the battery, which is an important parameter to characterize the battery life and the operating state of the battery, and an important symbol to measure the difficulty of the transmission of electrons and ions in the electrode. The internal resistance also reflects the health of the battery. The intern...
    more
  • Frequently Asked Questions about Commercial Battery Storage Systems

    Frequently Asked Questions about Commercial Battery Storage Systems

    Feb , 20 2025
    At a Glance Discover the integral role of commercial battery storage systems in the transition to sustainable energy. This blog provides essential answers to commonly asked questions, offering clarity on how these systems operate, their benefits, capacity, and longevity. Dive deeper into the distinctions between commercial, residential, and grid-scale energy storage solutions, and get an inside lo...
    more
  • Industrial and commercial energy storage liquid cooling and air conditioning refrigeration comparison

    Industrial and commercial energy storage liquid cooling and air conditioning refrigeration comparison

    Feb , 28 2025
    A detailed comparison of liquid cooling and air conditioning refrigeration technologies in industrial and commercial energy storage systems, covering many aspects such as working principle, performance, cost, and maintenance: 1. Working principle Liquid cooling system How it works: Circulate inside or outside the battery pack through a liquid medium (such as water, glycol solution, or special cool...
    more
  • Classification of DC Power Supplies

    Classification of DC Power Supplies

    Mar , 01 2025
    DC regulated power supply classification methods, according to the type of output power supply DC regulated power supply and AC regulated power supply; according to the connection between the regulated circuit and the load DC regulated power supply series regulated power supply and parallel regulated power supply; according to the operating state of the adjustment tube is divided into linear regul...
    more
  • Difference between kVA and kw

    Difference between kVA and kw

    Mar , 15 2025
    kVA is the unit of apparent power and kw is the unit of active power. In alternating current, apparent power does not indicate the actual power consumed in the circuit, but rather the maximum power that can be supplied or the maximum active power consumed in an alternating current circuit. In the case of active power, it is the power needed to enable the equipment to work properly, such as the ele...
    more
  • What Is UPS Input Power Factor and Why It Matters

    What Is UPS Input Power Factor and Why It Matters

    Apr , 12 2025
    Power factor (pf) is the difference between the actual energy consumed in an AC circuit and the apparent power. It will be calculated as a decimal or percentage between 0-1 pf and 0-100%, i.e. 0.9 pF=90%. Meaning of UPS power factor UPS input power factor UPS input power factor is the ratio of UPS input active power to input power. UPS is not only a part of the power supply, but also the load of t...
    more
  • An Overview of HV Substation Equipment — with Integration of High-Current DC Charging Systems

    An Overview of HV Substation Equipment — with Integration of High-Current DC Charging Systems

    May , 24 2025
    Each operating device in a high-voltage substation serves a vital role. Their shapes and sizes vary depending on their location and purpose, but together they ensure safe, stable, and efficient operation of the entire installation. 1. Switchgear: The Functional Core of a Substation Switchgear consists of various components like circuit breakers, disconnectors, earthing switches, and instrument tra...
    more
  • Calculation of the heat generation of lithium batteries

    Calculation of the heat generation of lithium batteries

    May , 24 2025
    The calculation of heat generation of lithium batteries is an important part of battery thermal management, involving multiple heat sources. The following are the detailed calculation methods and steps: 1. Main source of heat The heat generation of lithium batteries mainly comes from the following parts: Joule heat (Qj) : The heat generated when current passes through the internal resistance of a ...
    more
  • Understanding Instantaneous Load and Charger Capacity Calculation in Substations

    Understanding Instantaneous Load and Charger Capacity Calculation in Substations

    Jun , 07 2025
    In modern substations, accurate power system design requires a clear understanding of instantaneous (transient) loads and how they impact equipment sizing, particularly for battery chargers in DC systems. This article breaks down the concept of transient loads, their implications, and how to properly calculate charger capacity under such conditions. 1. What Is an Instantaneous (Transient) Load? A ...
    more
  • What are the differences between energy storage battery management systems and power battery management systems?

    What are the differences between energy storage battery management systems and power battery management systems?

    Jun , 13 2025
    The energy storage battery management system (BMS) and the power battery BMS are very similar in overall structure and core functions, but due to different application scenarios, there are obvious differences between the two in design logic, communication protocol, hardware structure, etc. Especially in high-security and high-scalability energy storage systems represented by EverExceed, BMS not on...
    more
  • Understanding Sine Wave vs. Square Wave in UPS Systems

    Understanding Sine Wave vs. Square Wave in UPS Systems

    Jun , 21 2025
    Uninterruptible Power Supplies (UPS) play a crucial role in ensuring the continuity and quality of power for mission-critical applications. One of the most important, yet often overlooked, technical aspects of a UPS system is its output waveform—namely, whether it delivers a sine wave, modified sine wave, or square wave. This waveform directly affects the performance, compatibility, and safety of ...
    more
first page << 1 ... 16 17 18 19 20 21 22 23 >> last page

a total of23 pages

leave a message
welcome to everexceed
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

home

products

about

contact