Blog
  • How to extend the power supply time of uninterruptible power supply (UPS)

    How to extend the power supply time of uninterruptible power supply (UPS)

    Aug , 03 2024
    There are two ways to extend the duration of an uninterruptible power supply: 1. Increase battery capacity. According to the length of time required to increase the number of batteries, but this method will cause a relative increase in battery charging time, but also increase the number of corresponding maintenance equipment, increase product size, resulting in an increase in the overall cost of U...
    more
  • Is the uninterrupted host suitable for computers  to reduce hard shutdowns

    Is the uninterrupted host suitable for computers to reduce hard shutdowns

    Aug , 17 2024
    The best offline intelligent UPS 3000va 1800w backup battery for  desktop computers provides complete power protection to protect  connected devices from surges, overvoltage, and undervoltage damage. Is the uninterrupted host suitable for computers? Advanced microprocessor control technology enables UPS to maintain high performance and reliability, effectively operating to reduce en...
    more
  • Four operating modes of UPS

    Four operating modes of UPS

    Aug , 23 2024
    1、Normal operation mode The principle of the power supply system is that when the utility power is normal, the machine will convert the alternating current of the utility power to direct current, and then charge the battery for use when the power is interrupted; it is emphasized here that the power supply system will not only act when the power is out, such as when the voltage is too low or high, ...
    more
  • Effect of electrolyte density and discharge on lead-acid batteries

    Effect of electrolyte density and discharge on lead-acid batteries

    Nov , 29 2024
    (1) Electrolyte density under different geographical and climatic strips. Whether the electrolyte density is high or low, it is necessary to make a specific analysis for the specific situation. Winter temperature is low, the viscosity of the electrolyte is large, it is not easy to penetrate the inside of the plate, the end voltage and capacity of the battery will decline, especially in the strong ...
    more
  • Influence of electrolyte on battery performance

    Influence of electrolyte on battery performance

    Nov , 29 2024
    (1) The relationship between the electrolyte concentration and the electromotive force and open circuit voltage of the lead-acid battery. The electromotive force and open circuit voltage of the lead-acid battery are related to the concentration of the electrolyte of the lead-acid battery than H2O4, and the electromotive force and open circuit voltage of the lead-acid battery also decrease with the...
    more
  • Measurement method and procedure of internal resistance of lead-acid battery

    Measurement method and procedure of internal resistance of lead-acid battery

    Dec , 07 2024
    1.Procedure for Battery Resistance Tests Use the following test procedure or use the capacity test procedure described in IEEE std. 1188. Step 1. Make sure all battery connections are clean, tight and free of corrosion. Pay attention to the insulation of tools to avoid short-circuiting of batteries. Step 2. Equalizing charge the batteries for 12hrs; Constant voltage & limited maximum current c...
    more
  • Industrial and commercial energy storage liquid cooling and air conditioning refrigeration comparison

    Industrial and commercial energy storage liquid cooling and air conditioning refrigeration comparison

    Feb , 28 2025
    A detailed comparison of liquid cooling and air conditioning refrigeration technologies in industrial and commercial energy storage systems, covering many aspects such as working principle, performance, cost, and maintenance: 1. Working principle Liquid cooling system How it works: Circulate inside or outside the battery pack through a liquid medium (such as water, glycol solution, or special cool...
    more
  • The principle of maintenance-free lead-acid batteries is based on the following aspects

    The principle of maintenance-free lead-acid batteries is based on the following aspects

    Mar , 07 2025
    1、Basic Electrochemical Principles The charging and discharging process of maintenance-free lead-acid batteries is based on electrochemical redox reactions. When discharging, metal lead is the negative pole, the oxidation reaction occurs, the electrode reaction formula is Pb +SO42-===PbSO4+ 2e-; lead dioxide is the positive pole, the reduction reaction occurs, the electrode reaction formula is PbO...
    more
  • Advantages of lead-acid colloidal batteries

    Advantages of lead-acid colloidal batteries

    Mar , 28 2025
    1. Long service life: The colloidal electrolyte can form a solid protective layer on the plate, reduce the bending and short circuit of the plate when used under heavy load, delay the softening and shedding of the plate, and make the battery life reach 1.5-2 times that of ordinary lead-acid batteries. 2. High safety: The electrolyte is solid, sealed, and never leaks. There is no acid mist gas prec...
    more
  • Why battery calibration?

    Why battery calibration?

    Apr , 03 2025
    Definition of Battery Calibration Battery calibration refers to the process of resetting and synchronizing the battery's power management system with the device's software to accurately gauge the battery's charge level and capacity. This procedure involves fully charging the battery, allowing it to drain completely, and then recharging it to recalibrate the device's battery indicator to provide ac...
    more
  • What Is UPS Input Power Factor and Why It Matters

    What Is UPS Input Power Factor and Why It Matters

    Apr , 12 2025
    Power factor (pf) is the difference between the actual energy consumed in an AC circuit and the apparent power. It will be calculated as a decimal or percentage between 0-1 pf and 0-100%, i.e. 0.9 pF=90%. Meaning of UPS power factor UPS input power factor UPS input power factor is the ratio of UPS input active power to input power. UPS is not only a part of the power supply, but also the load of t...
    more
  • How to maintain the consistency of lithium batteries

    How to maintain the consistency of lithium batteries

    Apr , 19 2025
    1. Balance control of the Battery Management System (BMS) Passive equalization: Through resistor discharge, the energy of high-charge cells is dissipated in the form of heat, making the voltages of each cell tend to be consistent. It is suitable for cost-sensitive scenarios, but the efficiency is relatively low. Active balancing: It transfers the energy of high-charge cells to low-charge cells thr...