Blog
  • Causes and methods of lithium battery life decline

    Causes and methods of lithium battery life decline

    Dec , 13 2024
    1. Battery aging: After multiple charge and discharge cycles, the chemical substances inside the lithium battery will gradually undergo irreversible changes. For example, the structure of the electrode material may be damaged when lithium ions are embedded and deembedded between the positive and negative electrodes. Taking the common lithium cobalt oxide cathode material as an example, with the in...
    more
  • Classification of DC Power Supplies

    Classification of DC Power Supplies

    Mar , 01 2025
    DC regulated power supply classification methods, according to the type of output power supply DC regulated power supply and AC regulated power supply; according to the connection between the regulated circuit and the load DC regulated power supply series regulated power supply and parallel regulated power supply; according to the operating state of the adjustment tube is divided into linear regul...
    more
  • Difference between kVA and kw

    Difference between kVA and kw

    Mar , 15 2025
    kVA is the unit of apparent power and kw is the unit of active power. In alternating current, apparent power does not indicate the actual power consumed in the circuit, but rather the maximum power that can be supplied or the maximum active power consumed in an alternating current circuit. In the case of active power, it is the power needed to enable the equipment to work properly, such as the ele...
    more
  • Advantages of lead-acid colloidal batteries

    Advantages of lead-acid colloidal batteries

    Mar , 28 2025
    1. Long service life: The colloidal electrolyte can form a solid protective layer on the plate, reduce the bending and short circuit of the plate when used under heavy load, delay the softening and shedding of the plate, and make the battery life reach 1.5-2 times that of ordinary lead-acid batteries. 2. High safety: The electrolyte is solid, sealed, and never leaks. There is no acid mist gas prec...
    more
  • How to choose the right lithium battery

    How to choose the right lithium battery

    Mar , 28 2025
    1. Identify application scenarios The purpose of lithium batteries directly affects parameter selection: Portable devices (mobile phones, drones, cameras): give priority to high energy density (such as ternary lithium batteries) and lightweight. Electric vehicles/power tools: require high discharge rate (C-rate) and long cycle life (such as lithium iron phosphate batteries). Energy storage systems...
    more
  • Difference between transformer insulation class and insulation strength

    Difference between transformer insulation class and insulation strength

    Mar , 29 2025
    Insulation level refers to the motor (or transformer) winding insulation material used in the heat resistance level. Motor and transformer insulation materials commonly used in the grade for A, E, B, F, H five. Each insulation level of insulation materials have corresponding limit allowable working temperature (motor or transformer winding the hottest point of temperature). Motor or transformer op...
    more
  • Why battery calibration?

    Why battery calibration?

    Apr , 03 2025
    Definition of Battery Calibration Battery calibration refers to the process of resetting and synchronizing the battery's power management system with the device's software to accurately gauge the battery's charge level and capacity. This procedure involves fully charging the battery, allowing it to drain completely, and then recharging it to recalibrate the device's battery indicator to provide ac...
    more
  • The advantages of lead-acid tubular plates

    The advantages of lead-acid tubular plates

    Apr , 19 2025
    1、To prevent the active substance from falling off: Tubular plate is in the positive plate on the conductive skeleton set with woven fibre tube, the tube into the active substance. This structure can effectively bind the active substance in the tube, even in the battery charging and discharging process, the plate is subjected to the stress of chemical reaction, the active substance is not easy to ...
    more
  • An Overview of HV Substation Equipment — with Integration of High-Current DC Charging Systems

    An Overview of HV Substation Equipment — with Integration of High-Current DC Charging Systems

    May , 24 2025
    Each operating device in a high-voltage substation serves a vital role. Their shapes and sizes vary depending on their location and purpose, but together they ensure safe, stable, and efficient operation of the entire installation. 1. Switchgear: The Functional Core of a Substation Switchgear consists of various components like circuit breakers, disconnectors, earthing switches, and instrument tra...
    more
  • Calculation of the heat generation of lithium batteries

    Calculation of the heat generation of lithium batteries

    May , 24 2025
    The calculation of heat generation of lithium batteries is an important part of battery thermal management, involving multiple heat sources. The following are the detailed calculation methods and steps: 1. Main source of heat The heat generation of lithium batteries mainly comes from the following parts: Joule heat (Qj) : The heat generated when current passes through the internal resistance of a ...
    more
  • The reason why LiFePO4 batteries cannot be charged but can be discharged below 0℃

    The reason why LiFePO4 batteries cannot be charged but can be discharged below 0℃

    Jun , 07 2025
    Why LiFePO4 Batteries Cannot Be Charged Below 0°C but Can Still Discharge The reason why LiFePO4 (Lithium Iron Phosphate) batteries, such as the EverExceed battery range, cannot be charged below 0°C yet can still discharge lies mainly in their electrochemical characteristics and safety considerations. 1. Why Charging Is Restricted at Low Temperatures Lithium Plating Risk: At sub-zero temperatures,...
    more
  • Understanding Instantaneous Load and Charger Capacity Calculation in Substations

    Understanding Instantaneous Load and Charger Capacity Calculation in Substations

    Jun , 07 2025
    In modern substations, accurate power system design requires a clear understanding of instantaneous (transient) loads and how they impact equipment sizing, particularly for battery chargers in DC systems. This article breaks down the concept of transient loads, their implications, and how to properly calculate charger capacity under such conditions. 1. What Is an Instantaneous (Transient) Load? A ...
    more
first page << 1 ... 21 22 23 24 25 26 >> last page

a total of26 pages

leave a message
welcome to everexceed
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

home

products

about

contact