Blog
  • The Impact of High Temperatures on Lead-Acid Batteries and Recommended Solutions

    The Impact of High Temperatures on Lead-Acid Batteries and Recommended Solutions

    Jul , 19 2025
    Lead-acid batteries are widely used in energy storage, telecom base stations, and UPS systems. However, their performance is significantly affected by ambient temperature—especially under high-temperature conditions, which can lead to rapid degradation and potential safety risks. Below are six key impacts of high temperature on lead-acid batteries and how to address them: 1. Short-Term Capacity Ga...
    more
  •  Protecting Digital Substations in a Hostile World: How EverExceed Supports Intelligent Electronics (IEDs)

    Protecting Digital Substations in a Hostile World: How EverExceed Supports Intelligent Electronics (IEDs)

    Jul , 19 2025
    In today’s power systems, digital substations have revolutionized control and monitoring with their intelligent electronic devices (IEDs). However, these advanced infrastructures are not immune to threats. In fact, their complexity and sensitivity demand a new level of protection—and that’s where EverExceed comes in. Understanding the Threats to Digital Substations Whether built from the ground up...
    more
  • Understanding Key UPS Terms: A Comprehensive Glossary for Power Protection

    Understanding Key UPS Terms: A Comprehensive Glossary for Power Protection

    Jul , 11 2025
    Understanding Key UPS Terms: A Comprehensive Glossary for Power Protection In today’s fast-paced world, uninterruptible power supplies (UPS) are crucial to ensuring the seamless operation of businesses and industries. Whether you are dealing with electrical outages or power surges, a UPS acts as a safeguard, ensuring that your critical systems remain operational. To help you better navigate the wo...
    more
  • Single-Phase vs. Three-Phase UPS: Which One is Right for Your Business?

    Single-Phase vs. Three-Phase UPS: Which One is Right for Your Business?

    Jul , 05 2025
    When selecting an Uninterruptible Power Supply (UPS) for your business or organization, understanding the difference between single-phase and three-phase systems is crucial. Both types provide reliable backup power to ensure your equipment continues running during unexpected power disruptions. However, their functionalities differ significantly, especially in large-scale industrial power applicati...
    more
  • 8 tips to avoid ground loops when dealing with signal level circuits

    8 tips to avoid ground loops when dealing with signal level circuits

    Jun , 27 2025
    Ground loops and signal noise General recommendation is to properly design and implement the facility's grounding system to avoid unwanted involvement of ground loops with the operation of the equipment. This kind of approach can also eliminate the need to consider equipment modifications and to engage in costly diagnostic efforts since most trouble involving common-mode noise is avoided in the si...
    more
  • Understanding Sine Wave vs. Square Wave in UPS Systems

    Understanding Sine Wave vs. Square Wave in UPS Systems

    Jun , 21 2025
    Uninterruptible Power Supplies (UPS) play a crucial role in ensuring the continuity and quality of power for mission-critical applications. One of the most important, yet often overlooked, technical aspects of a UPS system is its output waveform—namely, whether it delivers a sine wave, modified sine wave, or square wave. This waveform directly affects the performance, compatibility, and safety of ...
    more
  • What are the benefits of high-rate discharge UPS lithium batteries?

    What are the benefits of high-rate discharge UPS lithium batteries?

    Jun , 21 2025
    High-Rate Discharge Lithium Battery for UPS: Rapid Backup Power for Critical Applications The primary role of a high-rate discharge lithium battery in an uninterruptible power supply (UPS) system is to deliver a large current output within a short period, ensuring stable operation during sudden power outages or voltage fluctuations. The EverExceed high-voltage UPS lithium battery series is designe...
    more
  • How Low-Voltage Active Power Filters Compensate for Harmonics in the Power Grid

    How Low-Voltage Active Power Filters Compensate for Harmonics in the Power Grid

    Jun , 16 2025
    With the increasing use of nonlinear loads such as variable frequency drives, rectifiers, and other power electronic devices, power grid harmonics have become a common problem in low-voltage electrical systems. Low-voltage active power filters (APFs) play a key role in detecting and mitigating harmonic distortion to improve power quality. Here’s how APFs work to actively compensate for harmonics i...
    more
  • What are the differences between energy storage battery management systems and power battery management systems?

    What are the differences between energy storage battery management systems and power battery management systems?

    Jun , 13 2025
    The energy storage battery management system (BMS) and the power battery BMS are very similar in overall structure and core functions, but due to different application scenarios, there are obvious differences between the two in design logic, communication protocol, hardware structure, etc. Especially in high-security and high-scalability energy storage systems represented by EverExceed, BMS not on...
    more