Blog
  • The difference between the first, second, and third levels of distribution boxes

    The difference between the first, second, and third levels of distribution boxes

    Jun , 22 2024
    What do the primary, secondary, and tertiary boxes of a distribution box mean? This is a relative issue. Let's make a hypothesis: a newly built residential area introduces a 10kV incoming line and builds a distribution room. The outgoing line from the low-voltage end of the transformer is 0.4kV to the distribution cabinet (primary distribution cabinet), then the outgoing line is led to the distrib...
    more
  • Maximum power point tracking algorithm for photovoltaic power generation

    Maximum power point tracking algorithm for photovoltaic power generation

    Jun , 22 2024
    1. Introduction Photovoltaic power generation is a technology that uses solar energy to convert light energy into electricity. In the photovoltaic power generation system, in order to obtain the maximum power generation power, it is necessary to track the change of solar radiation intensity in real time, and adjust the working state of the photovoltaic module to keep near the maximum power point. ...
    more
  • Influence of lithium analysis on battery capacity

    Influence of lithium analysis on battery capacity

    Jun , 27 2024
    I. Introduction The phenomenon of lithium evolution is an important problem affecting the capacity of lithium batteries. This article will discuss the impact of lithium analysis on battery capacity with you in detail, and analyze its causes and solutions. Second, the impact of lithium on battery capacity 1. Loss of active lithium ions Lithium evolution causes some of the lithium ions to form lithi...
    more
  • Analysis and application of charge and discharge curve of lithium battery

    Analysis and application of charge and discharge curve of lithium battery

    Jun , 27 2024
    Abstract: In this paper, the analysis method of charge and discharge curve of lithium battery is introduced in detail, including charge efficiency, discharge characteristics, capacity evaluation, internal resistance evaluation and cycle life evaluation. Through the interpretation of the charge and discharge curve, the performance and characteristics of lithium batteries can be deeply understood, w...
    more
  • Advantages and disadvantages of constant voltage and current power supply

    Advantages and disadvantages of constant voltage and current power supply

    Jul , 06 2024
    The advantages of constant voltage and current power supply include flexibility, stability, protection function, adjustability, and high efficiency, while the disadvantages mainly include high cost, large volume, thermal management requirements, and response time. 1. Advantages: a. Flexibility: A constant voltage and current power supply can provide stable current or voltage output as needed, suit...
    more
  • Explanation of terms related to UPS power supply

    Explanation of terms related to UPS power supply

    Jul , 06 2024
    Transient Recovery Time: The time it takes for the output voltage to return to the specified range when there is a sudden change in load (0‐100%, 100%‐0), usually on the order of seconds (ms). Filter: a device used to eliminate noise, the input or output filtered to obtain a pure contention of the alternating current. Shielding: The use of physical principles, used to isolate the electromagnetic r...
    more
  • The characteristics and principle analysis of internal resistance of lithium battery

    The characteristics and principle analysis of internal resistance of lithium battery

    Jul , 12 2024
    The internal resistance of the battery is one of the most important characteristic parameters of the battery, which is an important parameter to characterize the battery life and the operating state of the battery, and an important symbol to measure the difficulty of the transmission of electrons and ions in the electrode. The internal resistance also reflects the health of the battery. The intern...
    more
  • Effect of electrolyte density and discharge on lead-acid batteries

    Effect of electrolyte density and discharge on lead-acid batteries

    Nov , 29 2024
    (1) Electrolyte density under different geographical and climatic strips. Whether the electrolyte density is high or low, it is necessary to make a specific analysis for the specific situation. Winter temperature is low, the viscosity of the electrolyte is large, it is not easy to penetrate the inside of the plate, the end voltage and capacity of the battery will decline, especially in the strong ...
    more
  • Irreversible lithium evolution of LiFePO4 batteries at low temperatures and its effect on battery performance degradation

    Irreversible lithium evolution of LiFePO4 batteries at low temperatures and its effect on battery performance degradation

    Dec , 07 2024
    Lithium evolution is the main failure problem faced by lithium-ion batteries during low temperature charging. Due to the low diffusion rate of lithium ions in the solid phase of graphite particles and in the liquid phase of the electrolyte at low temperatures, the negative polarization increases during charging and lithium evolution occurs, and the precipitated lithium metal is divided into revers...
    more
  • Classification of DC Power Supplies

    Classification of DC Power Supplies

    Mar , 01 2025
    DC regulated power supply classification methods, according to the type of output power supply DC regulated power supply and AC regulated power supply; according to the connection between the regulated circuit and the load DC regulated power supply series regulated power supply and parallel regulated power supply; according to the operating state of the adjustment tube is divided into linear regul...
    more
  • The principle of maintenance-free lead-acid batteries is based on the following aspects

    The principle of maintenance-free lead-acid batteries is based on the following aspects

    Mar , 07 2025
    1、Basic Electrochemical Principles The charging and discharging process of maintenance-free lead-acid batteries is based on electrochemical redox reactions. When discharging, metal lead is the negative pole, the oxidation reaction occurs, the electrode reaction formula is Pb +SO42-===PbSO4+ 2e-; lead dioxide is the positive pole, the reduction reaction occurs, the electrode reaction formula is PbO...
    more
  • Difference between kVA and kw

    Difference between kVA and kw

    Mar , 15 2025
    kVA is the unit of apparent power and kw is the unit of active power. In alternating current, apparent power does not indicate the actual power consumed in the circuit, but rather the maximum power that can be supplied or the maximum active power consumed in an alternating current circuit. In the case of active power, it is the power needed to enable the equipment to work properly, such as the ele...
    more
first page << 1 ... 18 19 20 21 22 23 24 >> last page

a total of24 pages