Blog
  • Causes, effects and measures of common problems of photovoltaic modules

    Causes, effects and measures of common problems of photovoltaic modules

    Apr , 26 2024
    First. Excessively high/low temperature Excessively high or low PV module temperatures can negatively affect the performance of the PV power system. The following are the causes and effects as well as the corresponding measures: 1. Causes of excessive temperature: solar radiation, heat conduction, shadow coverage, etc. Impact: Reduces the conversion efficiency of the module. Excessive temperature ...
    more
  • Measures to suppress harmonics

    Measures to suppress harmonics

    May , 11 2024
    The fundamental cause of harmonic generation is due to nonlinear loads. When the current flows through the load and does not have a linear relationship with the applied voltage, it forms a non sinusoidal current, resulting in harmonics. The suppression of harmonics in the power system is to reduce or eliminate the harmonic current injected into the system, in order to control the harmonic voltage ...
    more
  • How Low Frequency UPS Safeguards Critical Information

    How Low Frequency UPS Safeguards Critical Information

    May , 11 2024
    What is a Low Frequency UPS? A Low Frequency Online UPS is a sophisticated power protection device that utilizes double conversion technology to provide continuous and clean power to connected equipment. Unlike traditional Offline UPS, where the load is directly powered by the mains until a power failure occurs, it continuously powers the load through an inverter, ensuring a seamless transition be...
    more
  • Differences in communication serial ports

    Differences in communication serial ports

    May , 16 2024
    RS-232 and RS-485 are two common serial communication standards, with the following main differences between them: Different transmission methods: RS-232 adopts a single end transmission method, and its data signal is relative to the signal ground, usually used for point-to-point communication; RS-485 adopts differential transmission mode, allowing multiple transceivers to be connected on the bus,...
    more
  • Air cooling and heat dissipation design of industrial and commercial energy storage system

    Air cooling and heat dissipation design of industrial and commercial energy storage system

    Jun , 14 2024
    1 Air cooling and heat dissipation design of industrial and commercial energy storage system Air cooling is the use of air as a heat exchange medium, the use of air to circulate in the battery pack, the use of the temperature difference between the battery module and the air for heat transfer, generally divided into passive air cooling and active air cooling. The main factors affecting its cooling...
    more
  • Industrial and commercial energy storage system liquid cooling design

    Industrial and commercial energy storage system liquid cooling design

    Jun , 14 2024
    1. Industrial and commercial energy storage system liquid cooling design For the high-rate charging and discharging process of large-scale battery packs, the cooling capacity of air cooling system can not meet the heat dissipation demand of battery packs. Liquid has a higher specific heat capacity and higher thermal conductivity than air, and the liquid cooling cooling speed is faster, which has a...
    more
  • Differences in communication serial ports

    Differences in communication serial ports

    Jun , 22 2024
    RS-232 and RS-485 are two common serial communication standards, with the following main differences between them: Different transmission methods: RS-232 adopts a single end transmission method, and its data signal is relative to the signal ground, usually used for point-to-point communication; RS-485 adopts differential transmission mode, allowing multiple transceivers to be connected on the bus,...
    more
  • The difference between the first, second, and third levels of distribution boxes

    The difference between the first, second, and third levels of distribution boxes

    Jun , 22 2024
    What do the primary, secondary, and tertiary boxes of a distribution box mean? This is a relative issue. Let's make a hypothesis: a newly built residential area introduces a 10kV incoming line and builds a distribution room. The outgoing line from the low-voltage end of the transformer is 0.4kV to the distribution cabinet (primary distribution cabinet), then the outgoing line is led to the distrib...
    more
  • Maximum power point tracking algorithm for photovoltaic power generation

    Maximum power point tracking algorithm for photovoltaic power generation

    Jun , 22 2024
    1. Introduction Photovoltaic power generation is a technology that uses solar energy to convert light energy into electricity. In the photovoltaic power generation system, in order to obtain the maximum power generation power, it is necessary to track the change of solar radiation intensity in real time, and adjust the working state of the photovoltaic module to keep near the maximum power point. ...
    more
  • Influence of lithium analysis on battery capacity

    Influence of lithium analysis on battery capacity

    Jun , 27 2024
    I. Introduction The phenomenon of lithium evolution is an important problem affecting the capacity of lithium batteries. This article will discuss the impact of lithium analysis on battery capacity with you in detail, and analyze its causes and solutions. Second, the impact of lithium on battery capacity 1. Loss of active lithium ions Lithium evolution causes some of the lithium ions to form lithi...
    more
  • Analysis and application of charge and discharge curve of lithium battery

    Analysis and application of charge and discharge curve of lithium battery

    Jun , 27 2024
    Abstract: In this paper, the analysis method of charge and discharge curve of lithium battery is introduced in detail, including charge efficiency, discharge characteristics, capacity evaluation, internal resistance evaluation and cycle life evaluation. Through the interpretation of the charge and discharge curve, the performance and characteristics of lithium batteries can be deeply understood, w...
    more
  • The characteristics and principle analysis of internal resistance of lithium battery

    The characteristics and principle analysis of internal resistance of lithium battery

    Jul , 12 2024
    The internal resistance of the battery is one of the most important characteristic parameters of the battery, which is an important parameter to characterize the battery life and the operating state of the battery, and an important symbol to measure the difficulty of the transmission of electrons and ions in the electrode. The internal resistance also reflects the health of the battery. The intern...
    more
first page << 1 ... 23 24 25 26 27 ... 32 >> last page

a total of32 pages

leave a message
welcome to everexceed
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

home

products

about

contact