Blog
  • Explanation of terms related to UPS power supply

    Explanation of terms related to UPS power supply

    Jul , 06 2024
    Transient Recovery Time: The time it takes for the output voltage to return to the specified range when there is a sudden change in load (0‐100%, 100%‐0), usually on the order of seconds (ms). Filter: a device used to eliminate noise, the input or output filtered to obtain a pure contention of the alternating current. Shielding: The use of physical principles, used to isolate the electromagnetic r...
    more
  • Effect of electrolyte density and discharge on lead-acid batteries

    Effect of electrolyte density and discharge on lead-acid batteries

    Nov , 29 2024
    (1) Electrolyte density under different geographical and climatic strips. Whether the electrolyte density is high or low, it is necessary to make a specific analysis for the specific situation. Winter temperature is low, the viscosity of the electrolyte is large, it is not easy to penetrate the inside of the plate, the end voltage and capacity of the battery will decline, especially in the strong ...
    more
  • Classification of DC Power Supplies

    Classification of DC Power Supplies

    Mar , 01 2025
    DC regulated power supply classification methods, according to the type of output power supply DC regulated power supply and AC regulated power supply; according to the connection between the regulated circuit and the load DC regulated power supply series regulated power supply and parallel regulated power supply; according to the operating state of the adjustment tube is divided into linear regul...
    more
  • Difference between kVA and kw

    Difference between kVA and kw

    Mar , 15 2025
    kVA is the unit of apparent power and kw is the unit of active power. In alternating current, apparent power does not indicate the actual power consumed in the circuit, but rather the maximum power that can be supplied or the maximum active power consumed in an alternating current circuit. In the case of active power, it is the power needed to enable the equipment to work properly, such as the ele...
    more
  • What Is UPS Input Power Factor and Why It Matters

    What Is UPS Input Power Factor and Why It Matters

    Apr , 12 2025
    Power factor (pf) is the difference between the actual energy consumed in an AC circuit and the apparent power. It will be calculated as a decimal or percentage between 0-1 pf and 0-100%, i.e. 0.9 pF=90%. Meaning of UPS power factor UPS input power factor UPS input power factor is the ratio of UPS input active power to input power. UPS is not only a part of the power supply, but also the load of t...
    more
  • How to maintain the consistency of lithium batteries

    How to maintain the consistency of lithium batteries

    Apr , 19 2025
    1. Balance control of the Battery Management System (BMS) Passive equalization: Through resistor discharge, the energy of high-charge cells is dissipated in the form of heat, making the voltages of each cell tend to be consistent. It is suitable for cost-sensitive scenarios, but the efficiency is relatively low. Active balancing: It transfers the energy of high-charge cells to low-charge cells thr...
    more
  • Reasons for PID in photovoltaic modules

    Reasons for PID in photovoltaic modules

    Apr , 25 2025
    1. Definition and Principle    - PID refers to the phenomenon of degradation of module performance in a PV module due to the presence of a potential difference between the cell and the bezel in a humid environment. When the potential difference inside the module is large enough, it causes ions in the encapsulation material to migrate, for example, sodium ions migrate from the glass ...
    more
  • An Overview of HV Substation Equipment — with Integration of High-Current DC Charging Systems

    An Overview of HV Substation Equipment — with Integration of High-Current DC Charging Systems

    May , 24 2025
    Each operating device in a high-voltage substation serves a vital role. Their shapes and sizes vary depending on their location and purpose, but together they ensure safe, stable, and efficient operation of the entire installation. 1. Switchgear: The Functional Core of a Substation Switchgear consists of various components like circuit breakers, disconnectors, earthing switches, and instrument tra...
    more
  • What are the benefits of high-rate discharge UPS lithium batteries?

    What are the benefits of high-rate discharge UPS lithium batteries?

    Jun , 21 2025
    High-Rate Discharge Lithium Battery for UPS: Rapid Backup Power for Critical Applications The primary role of a high-rate discharge lithium battery in an uninterruptible power supply (UPS) system is to deliver a large current output within a short period, ensuring stable operation during sudden power outages or voltage fluctuations. The EverExceed high-voltage UPS lithium battery series is designe...
    more
  • 8 tips to avoid ground loops when dealing with signal level circuits

    8 tips to avoid ground loops when dealing with signal level circuits

    Jun , 27 2025
    Ground loops and signal noise General recommendation is to properly design and implement the facility's grounding system to avoid unwanted involvement of ground loops with the operation of the equipment. This kind of approach can also eliminate the need to consider equipment modifications and to engage in costly diagnostic efforts since most trouble involving common-mode noise is avoided in the si...
    more
  • The Impact of High Temperatures on Lead-Acid Batteries and Recommended Solutions

    The Impact of High Temperatures on Lead-Acid Batteries and Recommended Solutions

    Jul , 19 2025
    Lead-acid batteries are widely used in energy storage, telecom base stations, and UPS systems. However, their performance is significantly affected by ambient temperature—especially under high-temperature conditions, which can lead to rapid degradation and potential safety risks. Below are six key impacts of high temperature on lead-acid batteries and how to address them: 1. Short-Term Capacity Ga...
    more
  • Understanding Compact Substations: Structure, Components, and EverExceed’s Smart Solutions

    Understanding Compact Substations: Structure, Components, and EverExceed’s Smart Solutions

    Aug , 16 2025
    1. Growing Demand for Power – The Role of Substations In today’s rapidly developing world, electricity demand is increasing at an unprecedented pace. Power generation plants — whether hydroelectric, thermal, or nuclear — are often located far from the main load centers due to geographical and resource constraints. To ensure reliable energy delivery, high-voltage transmission networks carry electri...
    more
first page << 1 ... 13 14 15 16 17 ... 21 >> last page

a total of21 pages

leave a message
welcome to everexceed
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

home

products

about

contact