Blog
  • Explanation of terms related to UPS power supply

    Explanation of terms related to UPS power supply

    Jul , 06 2024
    Transient Recovery Time: The time it takes for the output voltage to return to the specified range when there is a sudden change in load (0‐100%, 100%‐0), usually on the order of seconds (ms). Filter: a device used to eliminate noise, the input or output filtered to obtain a pure contention of the alternating current. Shielding: The use of physical principles, used to isolate the electromagnetic r...
    more
  • Frequently Asked Questions about Commercial Battery Storage Systems

    Frequently Asked Questions about Commercial Battery Storage Systems

    Feb , 20 2025
    At a Glance Discover the integral role of commercial battery storage systems in the transition to sustainable energy. This blog provides essential answers to commonly asked questions, offering clarity on how these systems operate, their benefits, capacity, and longevity. Dive deeper into the distinctions between commercial, residential, and grid-scale energy storage solutions, and get an inside lo...
    more
  • Industrial and commercial energy storage liquid cooling and air conditioning refrigeration comparison

    Industrial and commercial energy storage liquid cooling and air conditioning refrigeration comparison

    Feb , 28 2025
    A detailed comparison of liquid cooling and air conditioning refrigeration technologies in industrial and commercial energy storage systems, covering many aspects such as working principle, performance, cost, and maintenance: 1. Working principle Liquid cooling system How it works: Circulate inside or outside the battery pack through a liquid medium (such as water, glycol solution, or special cool...
    more
  • Classification of DC Power Supplies

    Classification of DC Power Supplies

    Mar , 01 2025
    DC regulated power supply classification methods, according to the type of output power supply DC regulated power supply and AC regulated power supply; according to the connection between the regulated circuit and the load DC regulated power supply series regulated power supply and parallel regulated power supply; according to the operating state of the adjustment tube is divided into linear regul...
    more
  • Difference between kVA and kw

    Difference between kVA and kw

    Mar , 15 2025
    kVA is the unit of apparent power and kw is the unit of active power. In alternating current, apparent power does not indicate the actual power consumed in the circuit, but rather the maximum power that can be supplied or the maximum active power consumed in an alternating current circuit. In the case of active power, it is the power needed to enable the equipment to work properly, such as the ele...
    more
  • Why battery calibration?

    Why battery calibration?

    Apr , 03 2025
    Definition of Battery Calibration Battery calibration refers to the process of resetting and synchronizing the battery's power management system with the device's software to accurately gauge the battery's charge level and capacity. This procedure involves fully charging the battery, allowing it to drain completely, and then recharging it to recalibrate the device's battery indicator to provide ac...
    more
  • What Is UPS Input Power Factor and Why It Matters

    What Is UPS Input Power Factor and Why It Matters

    Apr , 12 2025
    Power factor (pf) is the difference between the actual energy consumed in an AC circuit and the apparent power. It will be calculated as a decimal or percentage between 0-1 pf and 0-100%, i.e. 0.9 pF=90%. Meaning of UPS power factor UPS input power factor UPS input power factor is the ratio of UPS input active power to input power. UPS is not only a part of the power supply, but also the load of t...
    more
  • How to maintain the consistency of lithium batteries

    How to maintain the consistency of lithium batteries

    Apr , 19 2025
    1. Balance control of the Battery Management System (BMS) Passive equalization: Through resistor discharge, the energy of high-charge cells is dissipated in the form of heat, making the voltages of each cell tend to be consistent. It is suitable for cost-sensitive scenarios, but the efficiency is relatively low. Active balancing: It transfers the energy of high-charge cells to low-charge cells thr...
    more
  • An Overview of HV Substation Equipment — with Integration of High-Current DC Charging Systems

    An Overview of HV Substation Equipment — with Integration of High-Current DC Charging Systems

    May , 24 2025
    Each operating device in a high-voltage substation serves a vital role. Their shapes and sizes vary depending on their location and purpose, but together they ensure safe, stable, and efficient operation of the entire installation. 1. Switchgear: The Functional Core of a Substation Switchgear consists of various components like circuit breakers, disconnectors, earthing switches, and instrument tra...
    more
  • Understanding Instantaneous Load and Charger Capacity Calculation in Substations

    Understanding Instantaneous Load and Charger Capacity Calculation in Substations

    Jun , 07 2025
    In modern substations, accurate power system design requires a clear understanding of instantaneous (transient) loads and how they impact equipment sizing, particularly for battery chargers in DC systems. This article breaks down the concept of transient loads, their implications, and how to properly calculate charger capacity under such conditions. 1. What Is an Instantaneous (Transient) Load? A ...
    more
  • What are the differences between energy storage battery management systems and power battery management systems?

    What are the differences between energy storage battery management systems and power battery management systems?

    Jun , 13 2025
    The energy storage battery management system (BMS) and the power battery BMS are very similar in overall structure and core functions, but due to different application scenarios, there are obvious differences between the two in design logic, communication protocol, hardware structure, etc. Especially in high-security and high-scalability energy storage systems represented by EverExceed, BMS not on...
    more
  • What are the benefits of high-rate discharge UPS lithium batteries?

    What are the benefits of high-rate discharge UPS lithium batteries?

    Jun , 21 2025
    High-Rate Discharge Lithium Battery for UPS: Rapid Backup Power for Critical Applications The primary role of a high-rate discharge lithium battery in an uninterruptible power supply (UPS) system is to deliver a large current output within a short period, ensuring stable operation during sudden power outages or voltage fluctuations. The EverExceed high-voltage UPS lithium battery series is designe...