Blog
  • Working principle of inverter

    Working principle of inverter

    Jul , 26 2024
    Input interface section: There are three signals in the input section: 12V DC input VIN, working enable voltage ENB, and panel current control signal DIM. VIN is provided by the Adapter, and ENB voltage is provided by the MCU on the motherboard, with a value of 0 or 3V. When ENB=0, the inverter does not work, while when ENB=3V, the inverter is in normal working condition; The DIM voltage is provid...
    more
  • Voltage drop calculation formula

    Voltage drop calculation formula

    Jul , 19 2024
    Voltage drop is a common issue in circuits. To calculate the decrease in voltage, we can use the following formula: Vout=Virn * (R2/(R1+R2)). This formula is based on the principle of resistance voltage division, where Vin represents the input voltage, Vout represents the output voltage, R1 represents the resistance value of the upper resistor, and R2 represents the resistance value of the lower r...
    more
  • The role of voltage transmitters

    The role of voltage transmitters

    Jul , 19 2024
    A voltage transmitter is a device used to convert an analog electrical signal generated by a sensor into a standard voltage or current signal output. It is widely used in the field of industrial automation and process control, and is also used to measure and monitor environmental parameters such as temperature, pressure, liquid level, etc. 1. What is a voltage transmitter Voltage Transmitter, abbr...
    more
  • What is the meaning of float charging for intelligent three‐stage charger in battery charger?

    What is the meaning of float charging for intelligent three‐stage charger in battery charger?

    Jul , 12 2024
    Float charging: Keep constant voltage charging, the charging current continues to decrease, and the battery is charged with maintenance type. When the charging current decreases to the set value or the charging time reaches the set value, the red light of sufficiency will be on, and the time will be about 2H, charging 10% of the power. Ordinary chargers are old‐fashioned chargers, charging, whethe...
    more
  • What are the meanings of deep discharge and  excessive discharge of UPS batteries

    What are the meanings of deep discharge and excessive discharge of UPS batteries

    Jul , 11 2024
    Deep discharge generally refers to the discharge of approximately 80% of  the rated capacity of a battery. After a period of use, there will inevitably be some active substances sinking in the power UPS power battery. If the active  substances are not activated in a timely manner, it will inevitably have some  impact on the capacity of the battery. Therefore, it is best to cond...
    more
  • Explanation of terms related to UPS power supply

    Explanation of terms related to UPS power supply

    Jul , 06 2024
    Transient Recovery Time: The time it takes for the output voltage to return to the specified range when there is a sudden change in load (0‐100%, 100%‐0), usually on the order of seconds (ms). Filter: a device used to eliminate noise, the input or output filtered to obtain a pure contention of the alternating current. Shielding: The use of physical principles, used to isolate the electromagnetic r...
    more
  • Advantages and disadvantages of constant voltage and current power supply

    Advantages and disadvantages of constant voltage and current power supply

    Jul , 06 2024
    The advantages of constant voltage and current power supply include flexibility, stability, protection function, adjustability, and high efficiency, while the disadvantages mainly include high cost, large volume, thermal management requirements, and response time. 1. Advantages: a. Flexibility: A constant voltage and current power supply can provide stable current or voltage output as needed, suit...
    more
  • What are the components of a modular UPS and the STS  switching switch

    What are the components of a modular UPS and the STS switching switch

    Jun , 26 2024
    What are the components of a modular UPS? The exact components may vary slightly depending on the specific  model and manufacturer, but the following are common components in  UPS systems: Power module The power module is the building block of modular UPS. Each power  module typically includes components such as rectifiers, inverters, and  DC-DC converters. These modules are ho...
    more
  • Five things that shorten the life of your UPS battery

    Five things that shorten the life of your UPS battery

    Jun , 26 2024
    One of the more common questions we get asked is how long a UPS battery will last. The ballpark, general answer is 3 to 5 years; however that answer is generallyl. And that’s because the life of your battery depends on a whole host of factors. Those factors are what we’re going to discuss today. Here are some of the things that can shorten the lifespan of your UPS battery. Let’s jump right in. Amb...