Blog
  • The principle of maintenance-free lead-acid batteries is based on the following aspects

    The principle of maintenance-free lead-acid batteries is based on the following aspects

    Mar , 07 2025
    1、Basic Electrochemical Principles The charging and discharging process of maintenance-free lead-acid batteries is based on electrochemical redox reactions. When discharging, metal lead is the negative pole, the oxidation reaction occurs, the electrode reaction formula is Pb +SO42-===PbSO4+ 2e-; lead dioxide is the positive pole, the reduction reaction occurs, the electrode reaction formula is PbO...
    more
  • Advantages of lead-acid colloidal batteries

    Advantages of lead-acid colloidal batteries

    Mar , 28 2025
    1. Long service life: The colloidal electrolyte can form a solid protective layer on the plate, reduce the bending and short circuit of the plate when used under heavy load, delay the softening and shedding of the plate, and make the battery life reach 1.5-2 times that of ordinary lead-acid batteries. 2. High safety: The electrolyte is solid, sealed, and never leaks. There is no acid mist gas prec...
    more
  • Why battery calibration?

    Why battery calibration?

    Apr , 03 2025
    Definition of Battery Calibration Battery calibration refers to the process of resetting and synchronizing the battery's power management system with the device's software to accurately gauge the battery's charge level and capacity. This procedure involves fully charging the battery, allowing it to drain completely, and then recharging it to recalibrate the device's battery indicator to provide ac...
    more
  • What Is UPS Input Power Factor and Why It Matters

    What Is UPS Input Power Factor and Why It Matters

    Apr , 12 2025
    Power factor (pf) is the difference between the actual energy consumed in an AC circuit and the apparent power. It will be calculated as a decimal or percentage between 0-1 pf and 0-100%, i.e. 0.9 pF=90%. Meaning of UPS power factor UPS input power factor UPS input power factor is the ratio of UPS input active power to input power. UPS is not only a part of the power supply, but also the load of t...
    more
  • How to maintain the consistency of lithium batteries

    How to maintain the consistency of lithium batteries

    Apr , 19 2025
    1. Balance control of the Battery Management System (BMS) Passive equalization: Through resistor discharge, the energy of high-charge cells is dissipated in the form of heat, making the voltages of each cell tend to be consistent. It is suitable for cost-sensitive scenarios, but the efficiency is relatively low. Active balancing: It transfers the energy of high-charge cells to low-charge cells thr...
    more
  • How electrolytic capacitor work for industrial battery charger

    How electrolytic capacitor work for industrial battery charger

    May , 16 2025
    I. What is electrolytic capacitor: 1. Electrolytic capacitor, as the “energy storage heart” of charger power module, bears the key tasks of filtering, voltage stabilization and transient response. Its large-capacity characteristics (up to tens of thousands of μF) can effectively absorb the pulsating current after rectification, reduce output ripple, and ensure that the charging process is stable a...
    more
  • The Impact of High Temperatures on Lead-Acid Batteries and Recommended Solutions

    The Impact of High Temperatures on Lead-Acid Batteries and Recommended Solutions

    Jul , 19 2025
    Lead-acid batteries are widely used in energy storage, telecom base stations, and UPS systems. However, their performance is significantly affected by ambient temperature—especially under high-temperature conditions, which can lead to rapid degradation and potential safety risks. Below are six key impacts of high temperature on lead-acid batteries and how to address them: 1. Short-Term Capacity Ga...
    more
  • The Hazards of Overcharging Lead-Acid Batteries

    The Hazards of Overcharging Lead-Acid Batteries

    Aug , 08 2025
    1. Significant Capacity Decline ① During overcharging, excessive chemical reactions occur inside the battery. The active material, lead dioxide, on the positive plate gradually becomes loose and loses its original structural stability, reducing its ability to participate in electrochemical reactions. ② The active material, spongy lead, on the negative plate also experiences a coarsening of particl...
    more
  • From Inconsistency to Reliability: EverExceed’s Lithium Battery Solutions

    From Inconsistency to Reliability: EverExceed’s Lithium Battery Solutions

    Aug , 16 2025
    Why Inconsistency Happens Lithium iron phosphate (LiFePO₄) battery packs naturally face inconsistency challenges over time. Manufacturing differences: Even with strict process control, slight variations in materials and production steps lead to differences between cells. Usage environment: Temperature, ventilation, and charging/discharging conditions accelerate these differences during operation. ...
    more
  • Understanding Compact Substations: Structure, Components, and EverExceed’s Smart Solutions

    Understanding Compact Substations: Structure, Components, and EverExceed’s Smart Solutions

    Aug , 16 2025
    1. Growing Demand for Power – The Role of Substations In today’s rapidly developing world, electricity demand is increasing at an unprecedented pace. Power generation plants — whether hydroelectric, thermal, or nuclear — are often located far from the main load centers due to geographical and resource constraints. To ensure reliable energy delivery, high-voltage transmission networks carry electri...
    more
  • EverExceed Lithium Battery PACK Process: Safety · Consistency · Efficiency

    EverExceed Lithium Battery PACK Process: Safety · Consistency · Efficiency

    Aug , 30 2025
    In today’s fast-growing new energy industry, the PACK process has become the key to evaluating the safety and reliability of battery systems. EverExceed, committed to delivering safe and reliable energy storage solutions, continuously optimizes PACK design and processes with years of expertise to ensure outstanding performance in global markets. Core Objectives of the PACK Process Safety: EverExce...
    more
  • How EverExceed Supports Redundancy in Telecom Power Systems

    How EverExceed Supports Redundancy in Telecom Power Systems

    Aug , 30 2025
    EverExceed provides advanced Telecom Power Solutions specifically designed with redundancy at their core, ensuring uninterrupted service and maximum uptime for telecom operators: N+1 Redundant Power Modules: Our ESB Series Telecom Power System features hot-swappable rectifiers and controllers, enabling seamless replacement or expansion without disrupting ongoing operations. Dual Power Inputs: Syst...