Blog
  • How to calculate the required ups load capacity?

    How to calculate the required ups load capacity?

    Oct , 19 2023
    Measured in “watts”, UPS load capacity is an important factor to consider when choosing a UPS (uninterruptible power supply). It determines how many electronic devices the UPS system can support. This post will tell you how to choose the right UPS with required UPS load capacity in the following four steps. Clarify UPS Measurement Units UPS systems are rated either in kilowatts (kW) or in kilo-vol...
    more
  • Inverter energy storage system on the role

    Inverter energy storage system on the role

    Oct , 27 2023
    First, the basic principle of inverter Inverter is a device that converts direct current to alternating current, its main principle is to use the switching characteristics of semiconductor devices (such as field effect tubes or thyristors, etc.) to control the power supply voltage and current through rapid switching, so as to achieve the conversion of direct current to the corresponding frequency ...
    more
  • UPS power supply power supply method and daily use precautions

    UPS power supply power supply method and daily use precautions

    Oct , 28 2023
    Today, whether it is a computer room or a data center, UPS power supply has played a vital position. When the UPS power supply is power supply in the municipal power, it is the role of the voltage regulator and filter to ensure the normal operation of the equipment; when the municipal power is interrupted, it can provide it by providing its DC power supply part (battery pack, diesel generator, etc...
    more
  • What are the characteristics of industrial UPS power supply

    What are the characteristics of industrial UPS power supply

    Oct , 28 2023
    Industrial UPS power supplies need to focus on the ability to operate in high-temperature environments. The design of components must adapt to the operational requirements of the industrial environment, adapt to high temperature and humidity, and also be able to cope with the corrosion of corrosive gases on the system. Under various operating conditions and continuous full load operation, industri...
    more
  • Method for providing the service life of valve-controlled closed lead acid Battery (VRLA)?

    Method for providing the service life of valve-controlled closed lead acid Battery (VRLA)?

    Nov , 03 2023
    1 Temperature affects battery life: thermal runaway causes temperature rise: Valve-controlled closed lead-acid battery (VRLA) charging when the internal gas recombination itself is an exothermal reaction, so that the battery temperature rises, floating charge flow increases, the gas evolution increases, and the battery temperature rises higher, the battery itself is a "poor liquid", tightly assemb...
    more
  • The working principle and control method of IGBT voltage modification method

    The working principle and control method of IGBT voltage modification method

    Nov , 03 2023
    Unlike the resistance method, the voltage method involves changing the driving voltage during the control phase to control voltage and current overshoot. There are approximately two methods to change the driving voltage. One is to achieve the change by dividing the driving voltage through a resistor, and the other is to change the output signal in the control chip (DSPFPGA), and then convert it in...
    more
  • Introduction to Data Center Cabinet Head Cabinet

    Introduction to Data Center Cabinet Head Cabinet

    Nov , 03 2023
    The column head cabinet is a cabinet used to allocate and manage one or more columns of cabinets in the same computer room, and has protection functions. In power room, communication equipment room, and large network room, column head cabinet is necessary and also necessary. 1. Basic concept of column head cabinet A column head cabinet is a cabinet located at the top (first position, equivalent to...
    more
  • Common methods in inverter operation command sources, programmable control inputs

    Common methods in inverter operation command sources, programmable control inputs

    Nov , 10 2023
    In addition to the frequency signal, there are two basic conditions for the operation of an inverter power supply, which are the operating signal of the inverter power supply. Common methods in the source of inverter operation commands The operation commands of the inverter power supply include start, stop, forward and reverse, forward and reverse, reset, etc. Like the pre rate setting mode of pow...
    more
  • Ground Design

    Ground Design

    Nov , 10 2023
    1、Introduction In the process of circuit design, grounding is a commonplace issue. The grounding method needs to be based on specific usage scenarios, and there is no universal grounding method. In this article, we will explain the essence of grounding issues, which is worth savoring carefully. 2、Classification of grounding The same hardware circuit may also have differences in grounding methods i...
    more
  • The role of energy storage system in microgrid

    The role of energy storage system in microgrid

    Nov , 16 2023
    1, improve the stability of distributed energy Distributed energy, such as solar energy, wind energy, biomass, and other renewable energy, is generally affected by the external environment such as light, temperature, wind, climate, and other factors. The power generation has the characteristics of randomness and instability. When the microgrid is disconnected from the grid and operates independent...
    more
  • What is single phase ups?

    What is single phase ups?

    Nov , 17 2023
    Single phase UPS has a single input and output source to the electrical equipment. With just one sinewave voltage, it only requires two wires to complete the circuit, one conductor and one neutral. Single phase UPS uninterruptible power supplies typically cover requirements up to 30 kVA. They are for servers, telecoms or computer systems, and network switches. Also they are along with any device t...
    more
  • What is the ups power factor?

    What is the ups power factor?

    Nov , 17 2023
    Power factor (pf) is the difference between actual energy consumed and the apparent powerin an AC circuit. It will calculate as a decimal or percentage between 0-1 pf and 0-100% i.e. 0.9 pF = 90%. UPS input power factor The UPS input power factor is the ratio of UPS input active power to input power. UPS is not only a part of power supply, but also a load on the utility power source. It means the ...