Blog
  • Maximum power point tracking algorithm for photovoltaic power generation

    Maximum power point tracking algorithm for photovoltaic power generation

    Jun , 22 2024
    1. Introduction Photovoltaic power generation is a technology that uses solar energy to convert light energy into electricity. In the photovoltaic power generation system, in order to obtain the maximum power generation power, it is necessary to track the change of solar radiation intensity in real time, and adjust the working state of the photovoltaic module to keep near the maximum power point. ...
    more
  • Factors affecting photovoltaic inverters

    Factors affecting photovoltaic inverters

    Jun , 22 2024
    1. The impact of altitude on photovoltaic inverters Altitude has a certain impact on the performance and reliability of photovoltaic inverters. As the altitude increases, the air pressure decreases and the air density decreases, which will lead to a decrease in the heat dissipation capacity of the photovoltaic inverter. In addition, the climatic conditions at high altitudes, such as temperature ch...
    more
  • Advantages and disadvantages of constant voltage and current power supply

    Advantages and disadvantages of constant voltage and current power supply

    Jul , 06 2024
    The advantages of constant voltage and current power supply include flexibility, stability, protection function, adjustability, and high efficiency, while the disadvantages mainly include high cost, large volume, thermal management requirements, and response time. 1. Advantages: a. Flexibility: A constant voltage and current power supply can provide stable current or voltage output as needed, suit...
    more
  • Explanation of terms related to UPS power supply

    Explanation of terms related to UPS power supply

    Jul , 06 2024
    Transient Recovery Time: The time it takes for the output voltage to return to the specified range when there is a sudden change in load (0‐100%, 100%‐0), usually on the order of seconds (ms). Filter: a device used to eliminate noise, the input or output filtered to obtain a pure contention of the alternating current. Shielding: The use of physical principles, used to isolate the electromagnetic r...
    more
  • Working principle of inverter

    Working principle of inverter

    Jul , 26 2024
    Input interface section: There are three signals in the input section: 12V DC input VIN, working enable voltage ENB, and panel current control signal DIM. VIN is provided by the Adapter, and ENB voltage is provided by the MCU on the motherboard, with a value of 0 or 3V. When ENB=0, the inverter does not work, while when ENB=3V, the inverter is in normal working condition; The DIM voltage is provid...
    more
  • Classification of DC Power Supplies

    Classification of DC Power Supplies

    Mar , 01 2025
    DC regulated power supply classification methods, according to the type of output power supply DC regulated power supply and AC regulated power supply; according to the connection between the regulated circuit and the load DC regulated power supply series regulated power supply and parallel regulated power supply; according to the operating state of the adjustment tube is divided into linear regul...
    more
  • Difference between kVA and kw

    Difference between kVA and kw

    Mar , 15 2025
    kVA is the unit of apparent power and kw is the unit of active power. In alternating current, apparent power does not indicate the actual power consumed in the circuit, but rather the maximum power that can be supplied or the maximum active power consumed in an alternating current circuit. In the case of active power, it is the power needed to enable the equipment to work properly, such as the ele...
    more
  • What Is UPS Input Power Factor and Why It Matters

    What Is UPS Input Power Factor and Why It Matters

    Apr , 12 2025
    Power factor (pf) is the difference between the actual energy consumed in an AC circuit and the apparent power. It will be calculated as a decimal or percentage between 0-1 pf and 0-100%, i.e. 0.9 pF=90%. Meaning of UPS power factor UPS input power factor UPS input power factor is the ratio of UPS input active power to input power. UPS is not only a part of the power supply, but also the load of t...
    more
  • 8 tips to avoid ground loops when dealing with signal level circuits

    8 tips to avoid ground loops when dealing with signal level circuits

    Jun , 27 2025
    Ground loops and signal noise General recommendation is to properly design and implement the facility's grounding system to avoid unwanted involvement of ground loops with the operation of the equipment. This kind of approach can also eliminate the need to consider equipment modifications and to engage in costly diagnostic efforts since most trouble involving common-mode noise is avoided in the si...
    more
  • Understanding Compact Substations: Structure, Components, and EverExceed’s Smart Solutions

    Understanding Compact Substations: Structure, Components, and EverExceed’s Smart Solutions

    Aug , 16 2025
    1. Growing Demand for Power – The Role of Substations In today’s rapidly developing world, electricity demand is increasing at an unprecedented pace. Power generation plants — whether hydroelectric, thermal, or nuclear — are often located far from the main load centers due to geographical and resource constraints. To ensure reliable energy delivery, high-voltage transmission networks carry electri...
    more
  • Three Steps to EMI Rectification

    Three Steps to EMI Rectification

    Aug , 22 2025
    Three Steps to EMI Rectification: From Locating Interference Sources to System-Level Noise Reduction Strategies In power system design, EMI problems are like an invisible electromagnetic storm, which can interfere with the normal operation of equipment if you are not careful. For EMI technicians, the rectification process is not only a technical task, but also a game with electromagnetic waves. To...
    more
  • Best Practices for Telecom Hardware Installation: Enhancing Performance with EverExceed Power Solutions

    Best Practices for Telecom Hardware Installation: Enhancing Performance with EverExceed Power Solutions

    Aug , 30 2025
    Telecom hardware installation is a critical process that requires careful planning and execution to ensure optimal performance and long-term reliability. From selecting the right equipment to implementing proper cable routing and ensuring effective power and grounding, there are numerous best practices that organizations must consider. By following these strategies, businesses can enhance their te...