Blog
  • Why Does Your UPS Trigger an Overload Alarm Even When Its Capacity Is Sufficient?

    Why Does Your UPS Trigger an Overload Alarm Even When Its Capacity Is Sufficient?

    Oct , 22 2026
    In data centers, industrial automation systems, medical equipment and other critical applications, a UPS may trigger an overload alarm even when the displayed load is well below its rated capacity. Why does this happen when the load is only 60%? The problem is not necessarily that the UPS is undersized. Nonlinear loads, such as servers, variable-frequency drives and rectifier-based power supplies,...
    more
  • 48V Telecom Power System: Managing Backup Power and Critical Loads

    48V Telecom Power System: Managing Backup Power and Critical Loads

    Oct , 29 2026
    Quick Answer In a 48V telecom power system, a power outage does not always mean that all equipment will shut down at the same time. When utility power fails, the rectifiers stop supplying normal DC power, and the battery takes over. If the outage continues and the battery voltage drops, the Low Voltage Disconnect (LVD) function may disconnect selected loads to prevent excessive battery discharge. ...
    more
  • How Do Grid Power, Diesel Generators, and Batteries Work Together to Keep Remote Telecom Base Stations Powered?

    How Do Grid Power, Diesel Generators, and Batteries Work Together to Keep Remote Telecom Base Stations Powered?

    Nov , 06 2026
    Remote telecom base stations often face challenges when grid power is unstable or unavailable. To maintain a continuous power supply, these sites may rely on a combination of grid power, diesel generators, and battery backup. However, having multiple power sources does not automatically guarantee reliable operation. The real challenge is coordinating when each source takes over, how the rectifier ...
    more
  • Customized UPS and High-Voltage Lithium Battery Solutions for Critical Power Applications

    Customized UPS and High-Voltage Lithium Battery Solutions for Critical Power Applications

    Nov , 06 2026
    Reliable backup power is essential for facilities where even a brief power interruption can affect operational continuity, equipment safety, and service availability. From public utilities and wastewater treatment plants to modern data centers, UPS systems must deliver stable power while meeting specific requirements for backup duration, load capacity, installation space, and system integration. C...
    more
  •  Why Does the Telecom Industry Use -48V DC? The Long-Standing Choice Behind Power Safety and Corrosion Control

    Why Does the Telecom Industry Use -48V DC? The Long-Standing Choice Behind Power Safety and Corrosion Control

    Nov , 10 2026
    From historical practice to modern telecom power systems, -48V was not an arbitrary choice. In telecom power systems, -48V does not mean that every point inside the equipment is 48V below ground. In a common system configuration, the positive DC pole is connected to the ground reference, while the negative pole serves as the power supply rail. Therefore, when measured relative to ground, the negat...
    more
first page << 1 ... 16 17 18 last page

a total of18 pages

leave a message
welcome to everexceed
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

home

products

about

contact