Blog
  • What is the meaning of float charging for intelligent three‐stage charger in battery charger?

    What is the meaning of float charging for intelligent three‐stage charger in battery charger?

    Jul , 12 2024
    Float charging: Keep constant voltage charging, the charging current continues to decrease, and the battery is charged with maintenance type. When the charging current decreases to the set value or the charging time reaches the set value, the red light of sufficiency will be on, and the time will be about 2H, charging 10% of the power. Ordinary chargers are old‐fashioned chargers, charging, whethe...
    more
  • Advantages and disadvantages of constant voltage and current power supply

    Advantages and disadvantages of constant voltage and current power supply

    Jul , 06 2024
    The advantages of constant voltage and current power supply include flexibility, stability, protection function, adjustability, and high efficiency, while the disadvantages mainly include high cost, large volume, thermal management requirements, and response time. 1. Advantages: a. Flexibility: A constant voltage and current power supply can provide stable current or voltage output as needed, suit...
    more
  • Differences in communication serial ports

    Differences in communication serial ports

    Jun , 22 2024
    RS-232 and RS-485 are two common serial communication standards, with the following main differences between them: Different transmission methods: RS-232 adopts a single end transmission method, and its data signal is relative to the signal ground, usually used for point-to-point communication; RS-485 adopts differential transmission mode, allowing multiple transceivers to be connected on the bus,...
    more
  • A brief introduction to EMI

    A brief introduction to EMI

    Jun , 14 2024
    What is an active power filter Active Power Filter (APF) is a new type of power electronic device used to dynamically suppress harmonics and compensate reactive power, which can compensate for harmonics and reactive power changes in magnitude and frequency. The reason why the active filter is called active, as the name suggests, the device needs to provide a power supply (to compensate for the har...
    more
  • Methods for reducing ripple voltage

    Methods for reducing ripple voltage

    Jun , 06 2024
    Brief introduction Ripple voltage is a voltage fluctuation in the output of a DC power supply, referring to the AC component of the output voltage. Excessive ripple voltage can have an impact on the normal operation of electronic devices, so reducing ripple voltage is an important issue that needs to be addressed in the power supply design process. This article will introduce some commonly used me...
    more
  • Commonly used industrial communication protocols

    Commonly used industrial communication protocols

    May , 31 2024
    1、Modbus protocol (1) Modbus packet type Modbus protocol is an application-layer message transmission protocol that can be transmitted on various media, and the transmission mode is divided into three types: ASCII, RTU (Remote Terminal Control System), and TCP.  There are multiple versions of the Modbus protocol for serial ports, but the following three are the most common: Modbus-RTU: In thi...
    more
  • A Brief Introduction To Filter Circuits

    A Brief Introduction To Filter Circuits

    May , 25 2024
    In the rectifier filter circuit, there are two parts of the circuit altogether, respectively the rectifier circuit and the filter circuit, the functions of the two are different, the function of the rectifier circuit is to convert the sine wave AC voltage, and the function of the filter circuit is to convert the unidirectional ripple voltage, and the functions of the two parts of the circuit work ...
    more
  • Differences in communication serial ports

    Differences in communication serial ports

    May , 16 2024
    RS-232 and RS-485 are two common serial communication standards, with the following main differences between them: Different transmission methods: RS-232 adopts a single end transmission method, and its data signal is relative to the signal ground, usually used for point-to-point communication; RS-485 adopts differential transmission mode, allowing multiple transceivers to be connected on the bus,...
    more
  • Measures to suppress harmonics

    Measures to suppress harmonics

    May , 11 2024
    The fundamental cause of harmonic generation is due to nonlinear loads. When the current flows through the load and does not have a linear relationship with the applied voltage, it forms a non sinusoidal current, resulting in harmonics. The suppression of harmonics in the power system is to reduce or eliminate the harmonic current injected into the system, in order to control the harmonic voltage ...
    more