Blog
  • Why Does Your UPS Trigger an Overload Alarm Even When Its Capacity Is Sufficient?

    Why Does Your UPS Trigger an Overload Alarm Even When Its Capacity Is Sufficient?

    Oct , 22 2026
    In data centers, industrial automation systems, medical equipment and other critical applications, a UPS may trigger an overload alarm even when the displayed load is well below its rated capacity. Why does this happen when the load is only 60%? The problem is not necessarily that the UPS is undersized. Nonlinear loads, such as servers, variable-frequency drives and rectifier-based power supplies,...
    more
  • Why Are 12V Lead Acid Batteries Commonly Limited to Around 250Ah (C10)?

    Why Are 12V Lead Acid Batteries Commonly Limited to Around 250Ah (C10)?

    Oct , 24 2026
    Introduction When selecting a 12V lead acid battery for UPS systems, telecommunications, solar energy storage, or backup power applications, buyers often notice that many standard products have capacities of 250Ah (C10) or less. Meanwhile, 2V lead acid batteries are widely available in much higher capacities, ranging from several hundred amp-hours to over 3,000Ah. Why is there such a difference? T...
    more
  • How to Plan a High-Voltage UPS Battery System for Reliable Backup Power and Future Expansion

    How to Plan a High-Voltage UPS Battery System for Reliable Backup Power and Future Expansion

    Nov , 12 2026
    As data centers, industrial facilities, and critical infrastructure continue to expand, reliable backup power has become increasingly important. A well-designed UPS battery system must not only provide sufficient backup power during outages but also accommodate future changes in load demand, runtime requirements, and facility capacity. High-voltage lithium battery systems are becoming an increasin...
    more
  • Why Do Devices Restart When UPS Output Voltage Is Normal? Check Grounding and Common-Mode Noise

    Why Do Devices Restart When UPS Output Voltage Is Normal? Check Grounding and Common-Mode Noise

    Nov , 17 2026
    Quick Answer When servers, instruments or communication devices restart intermittently despite normal UPS output voltage and frequency, the cause may not be the UPS itself. Neutral-to-ground voltage (N-PE), common-mode noise, grounding impedance and cable connections can also affect sensitive electronic loads. A reliable diagnosis should go beyond checking the UPS output voltage. It should examine...
    more
first page << 1 ... 13 14 15 last page

a total of15 pages

leave a message