| MODEL |
PL3 6KS |
PL3 6KL |
PL3 10KS |
PL3 10KL |
PL3 15KS |
PL3 15KL |
PL3 20KS |
PL3 20KL |
| Capacity |
6kVA/6kW |
6kVA/6kW |
10kVA/10kW |
10kVA/10kW |
15kVA/15kW |
15kVA/15kW |
20kVA/20kW |
20kVA/20kW |
| Phase |
1 Phase in/1 Phase out |
| INPUT |
| Nominal Voltage |
208/220/230/240VAC (L-N Voltage), L+N+PE |
| Input Voltage Range |
176~300VAC (L-N voltage)@100%load; 176~110VAC, linearly derating from 100% to 50% load |
| Input Frequency Range |
50/60±6Hz |
| Input Power Factor |
>0.99 |
| Input Current Distortion (THDi) |
<5% |
| Bypass Voltage Range |
-40%~20% of nominal voltage, adjustable |
| OUTPUT |
| Nominal Votage |
208/220/230/240VAC, L+N+PE |
| Voltage Regulation |
± 1 % |
| Nominal Frequency |
50/60Hz, adjustable |
| Output Frequency |
Line Mode:50/60±1/2/3/4/5/6Hz , adjustable ; Battery Mode: 50/60±0.001 Hz |
| Output Power Factor |
1 |
| Output Voltage Distortion (THDu) |
≤2%@linear load; ≤5%@non-linear load |
| Transfer Time |
Line mode to Battery mode, 0ms; Inverter to Bypass, 0ms (Synchronized);
Bypass to Inverter, 0ms(Synchronized); ECO to Battery Mode, 2ms (Typical Time)
|
| Crest Ratio |
3:1 |
|
Overload Capacity
(Line Mode)
|
10 min @ 102%~110% load;
1 min @ 110%~130% load;
10s @130%~150% load;
200 ms @ >150% load
|
30 min @ 102%~110% load;
10 min @ 110%~130% load;
30s @130%~150% load;
200 ms @ >150% load
|
30 min @ 102%~110% load;
10 min @ 110%~130% load;
30s @130%~150% load;
500 ms @ >150% load
|
| Overload Capacity (Battery Mode) |
10 min @ 102%~110% load;
1 min @ 110%~130% load;
10s @130%~150% load;
200 ms @ >150% load
|
10 min @ 102%~110% load;
1 min @ 110%~130% load;
10s @130%~150% load;
500 ms @ >150% load
|
| Output Short Circuit Protection |
Line Mode: Current limitation; Battery Mode: Current limitation; Bypass Mode: Breaker |
| BATTERY |
| Battery Type |
Sealed Lead Acid Maintanance Free (VRLA) |
| Nominal Voltage |
192~240VDC, adjustable |
| Charging Voltage |
Floating Charge, 2.25V/cell; Boost Charge, 2.35V/cell |
| Battery Number&Capacity |
16 pcs,
12V/7Ah
|
External |
16 pcs,
12V/9Ah
|
External |
16 pcs,
12V/9Ah
|
External |
16 pcs*2strings, 12V/9Ah |
External |
| Charging Current |
1A |
1~12A,
adjustable
|
1A |
1~12A,
adjustable
|
1A |
1~12A,
adjustable
|
1~2A, adjustable, default 2A |
1~12A,
adjustable
|
| Charging Mode |
Two Satges (CC/Floating) or Three Stages (CC/CV/Floating, settable) |
| Typical Recharge Time |
9 hours recharge to 90% |
Depending on the capacity of external batteries |
9 hours recharge to 90% |
Depending on the capacity of external batteries |
9 hours recharge to 90% |
Depending on the capacity of external batteries |
9 hours recharge to 90% |
Depending on the capacity of external batteries |
| Battery Protection |
Battery Leakage<500µA, Over Voltage Protection, Under Voltage Protection,
Over Current Protection; Battery Deep Discharge Protection
|
| EFFICIENCY |
| Line Mode |
95.5% (Max) |
94% (Max) |
| Battery Mode |
95% (Max) |
92% (Max) |
| ECO Mode |
98.5% |
98% |
| INDICATORS |
| LCD Panel |
UPS status, Battery Level, Load Level, Input/Outpt/Battery Voltage, Fault&Alarm Code |
| Audible Alarm |
Utility Failure, Battery Voltage Low, Overload, System Fault |
| MANAGEMENT |
| Interface |
RS232 ,USB, Parallel Card, EPO Port, SNMP Card (Optional), Relay Card (Optional) |
| ENVIRONMENT |
| Operating Temperature |
0~40℃ |
| Operating Humidity |
0~95% RH, non-condensing |
| Storage Temperature |
-15~60℃ (Battery: 0-40℃) |
| Altitude |
<1000m, derating 1% per 100m from 1000 ~ 2000m |
| Noise (1Meter Away) |
<55dB |
<60dB |
| PHYSICAL |
|
Dimension
(W*D*H, unit:mm)
|
250x523x602 |
190x437x322 |
250x523x602 |
190x437x322 |
251*635*315 |
215*635*722 |
251*635*315 |
215*635*722 |
| Net Weight (kg) |
68 |
15 |
75 |
17 |
87 |
21 |
122 |
23 |
| Color |
Black ( RAL9004) |
| STANDARDS |
| Safety |
IEC 62040-1:2017 |
| EMC |
IEC 62040-2:2018 |
| Performance |
IEC 62040-3:2011 |
| Battery |
IEC 60896-22:2004 |