| MODEL |
PL3 RM1KS |
PL3 RM1KL |
PL3 RM2KS |
PL3 RM2KL |
PL3 RM3KS |
PL3 RM3KL |
| Capacity |
1kVA/1kW |
1kVA/1kW |
2kVA/2kW |
2kVA/2kW |
3kVA/3kW |
3kVA/3kW |
| Phase |
1 Phase in/1 Phase out |
| INPUT |
|
| Nominal Voltage |
208/220/230/240VAC (L-N Voltage), L+N+PE |
| Input Voltage Range |
110~300VAC |
| Input Frequency Range |
50/60±6Hz |
| Input Power Factor |
>0.99 |
| Input Current Distortion (THDi) |
≤4%(linear load);≤5%(non-;linear load) |
| Bypass Voltage Range |
-40%~20% of nominal voltage, adjustable |
| OUTPUT |
|
| Nominal Votage |
208/220/230/240VAC , L+N+PE |
| Voltage Regulation |
± 1 % |
| Nominal Frequency |
50/60Hz, adjustable |
| Output Frequency |
Line Mode:50/60±1/2/3/4/5/6Hz , adjustable ; Battery Mode: 50/60±0.001 Hz |
| Output Power Factor |
1 |
| Output Voltage Distortion (THDu) |
≤2%@linear load; ≤5%@non-linear load |
| Transfer Time |
Line mode to Battery mode, 0ms; Inverter to Bypass, 4ms (Synchronized);Bypass to Inverter, 4ms(Synchronized); ECO to Battery Mode, 6ms (Typical Time) |
| Crest Ratio |
3:1 |
|
Overload Capacity
(Line Mode)
|
30 min @ 102%~110% load;10 min @ 110%~130% load;30s @130%~150% load;200 ms @ >150% load |
|
Overload Capacity
(Battery Mode)
|
1 min @ 102%~110% load;10s @ 110%~130% load;3s @130%~150% load;200 ms @ >150% load |
|
Overload Capacity
(Bypass Mode)
|
Depending the input breaker (10A) |
Depending the input breaker (20A) |
| Output Short Circuit Protection |
Line Mode: Current limitation; Battery Mode: Current limitation; Bypas Mode: Breaker |
| BATTERY |
|
| Battery Type |
Sealed Lead Acid Maintanance Free (VRLA) |
| Nominal Voltage |
24VDC |
36VDC |
48VDC |
72VDC |
72VDC |
96VDC |
| Charging Voltage |
Floating |
| Battery Number&Capacity |
2 pcs, 12V/9Ah |
External |
4 pcs, 12V/9Ah |
External |
6pcs, 12V/9Ah |
External |
| Charging Current |
1A-4A,adjustable, default 1A |
1~12A, adjustable |
1A-4A,adjustable, default 1A |
1~12A, adjustable |
1A-4A,adjustable, default 1A |
1~12A, adjustable |
| Charging Mode |
Two Satges (CC/Floating) or Three Stages (CC/CV/Floating, settable) |
| Battery Protection |
Battery Leakage<500µA, Over Voltage Protection, Under Voltage Protection, Over Current Protection;Battery Deep Discharge Protection |
| EFFICIENCY |
|
| Line Mode |
94.5% (Max) |
95.5% (Max) |
95.5% (Max) |
| Battery Mode |
88.5% (Max) |
89.5% (Max) |
91.5% (Max) |
| ECO Mode |
98% |
| INDICATORS |
|
| LCD Panel |
UPS status, Battery Level, Load Level, Input/Outpt/Battery Voltage, Fault&Alarm Code |
| Audible Alarm |
Utility Failure, Battery Voltage Low, Overload, System Fault |
| MANAGEMENT |
|
| Interface |
RS232 ,USB, EPO Port, SNMP Card (Optional), Relay Card (Optional) |
| ENVIRONMENT |
|
| Operating Temperature |
0~40℃ |
| Operating Humidity |
0~95% RH, non-condensing |
| Storage Temperature |
-15~60℃ (Battery: 0-40℃) |
| Altitude |
<1000m, derating 1% per 100m from 1000~ 2000m |
| Noise (1Meter Away) |
<50dB@ 1 meter away |
| PHYSICAL |
|
| Dimension(W*D*H, unit:mm) |
440*379*86 |
440*379*86 |
440*568*86 |
440*450*86 |
445*560*86 |
440*450*86 |
| Net Weight (kg) |
8.6 |
4 |
18 |
8 |
24 |
10 |
| Color |
Black ( RAL9004) |
| STANDARDS |
|
| Safety |
IEC 62040-1:2017 |
| EMC |
IEC 62040-2:2018 |
| Performance |
IEC 62040-3:2011 |
| Battery |
IEC 60896-22:2004 |