Blog
  • Inverter common fault contents and solutions

    Inverter common fault contents and solutions

    May , 11 2024
    As an important component of the entire power plant, inverters can detect almost all power plant parameters for both DC components and grid connected equipment. If there is an abnormality, the health status of the supporting equipment in the power station can be checked through the feedback information from the inverter. Below are some common fault information and handling methods for photovoltaic...
    more
  • The difference and comparison of advantages between P-type and N-type components

    The difference and comparison of advantages between P-type and N-type components

    May , 11 2024
    Materials and Structure of a Solar Cell The construction of a particular solar cell is going to vary slightly depending on the specific technology that is utilized to manufacture it. In most solar cells, there is an aluminum back surface field and a P-N Junction. At the P-N junction, there are p-type crystalline silicon wafers that are positively charged and n-type crystalline silicon wafers that ...
    more
  • Lead-acid battery failure model

    Lead-acid battery failure model

    May , 11 2024
    The most common failure modes are:   - Softening or shedding of the active material.  During discharge the lead oxide (PbO2) of the positive plate is transformed into lead sulfate (PbSO4), and back to lead oxide during charging. Frequent cycling will reduce cohesion of the positive plate material due to the higher volume of lead sulfate compared to lead oxide.    Corrosion...
    more
  • How Low Frequency UPS Safeguards Critical Information

    How Low Frequency UPS Safeguards Critical Information

    May , 11 2024
    What is a Low Frequency UPS? A Low Frequency Online UPS is a sophisticated power protection device that utilizes double conversion technology to provide continuous and clean power to connected equipment. Unlike traditional Offline UPS, where the load is directly powered by the mains until a power failure occurs, it continuously powers the load through an inverter, ensuring a seamless transition be...
    more
  • Measures to suppress harmonics

    Measures to suppress harmonics

    May , 11 2024
    The fundamental cause of harmonic generation is due to nonlinear loads. When the current flows through the load and does not have a linear relationship with the applied voltage, it forms a non sinusoidal current, resulting in harmonics. The suppression of harmonics in the power system is to reduce or eliminate the harmonic current injected into the system, in order to control the harmonic voltage ...
    more
  • Causes, effects and measures of common problems of photovoltaic modules

    Causes, effects and measures of common problems of photovoltaic modules

    Apr , 26 2024
    First. Excessively high/low temperature Excessively high or low PV module temperatures can negatively affect the performance of the PV power system. The following are the causes and effects as well as the corresponding measures: 1. Causes of excessive temperature: solar radiation, heat conduction, shadow coverage, etc. Impact: Reduces the conversion efficiency of the module. Excessive temperature ...
    more
  • The difference between energy storage converter and grid-connected inverter

    The difference between energy storage converter and grid-connected inverter

    Apr , 26 2024
    Energy Storage Converter Energy storage converters (PCS), also known as "bi-directional energy storage inverters", are the core components of the two-way flow of electricity between the energy storage system and the grid, and are used to control the charging and discharging processes of the battery, and to perform the conversion of AC and DC currents. In the absence of grid, it can directly supply...
    more
  • Uninterruptible Power Supply UPS System for Computers Protection

    Uninterruptible Power Supply UPS System for Computers Protection

    Apr , 26 2024
    What is A UPS System? An Uninterruptible Power Supply (UPS) system is an electrical device that provides emergency power to a computer or other electronic equipment in the event of a power outage or electrical disturbance. It acts as a backup power source, allowing the connected devices to continue functioning for a certain period or providing sufficient time for a safe shutdown. How UPS System fo...
    more
  • The main components of inverters, converter tools

    The main components of inverters, converter tools

    Apr , 26 2024
    The main two parts are rectifier and inverter. Some of the main components of the inverter The first to convert AC voltage into DC voltage; The second one converts this DC voltage into an AC voltage with variable amplitude and frequency. Therefore, they together form an AC to AC converter tool that can be placed between a regular power grid and loads with special requirements for voltage and frequ...