Blog
  • What is the meaning of float charging for intelligent three‐stage charger in battery charger?

    What is the meaning of float charging for intelligent three‐stage charger in battery charger?

    Jul , 12 2024
    Float charging: Keep constant voltage charging, the charging current continues to decrease, and the battery is charged with maintenance type. When the charging current decreases to the set value or the charging time reaches the set value, the red light of sufficiency will be on, and the time will be about 2H, charging 10% of the power. Ordinary chargers are old‐fashioned chargers, charging, whethe...
    more
  • Lithium battery life The reason for the slow charging speed

    Lithium battery life The reason for the slow charging speed

    Dec , 13 2024
    1. Electrical problems: Insufficient power of the charger is one of the common reasons for slow charging speed. If the output current of the charger used is small and cannot meet the maximum charging current requirements of the battery, the charging speed will be limited. For example, a lithium battery mobile phone that supports fast charging, the original charger output current is 3A, and the cha...
    more
  • Classification of DC Power Supplies

    Classification of DC Power Supplies

    Mar , 01 2025
    DC regulated power supply classification methods, according to the type of output power supply DC regulated power supply and AC regulated power supply; according to the connection between the regulated circuit and the load DC regulated power supply series regulated power supply and parallel regulated power supply; according to the operating state of the adjustment tube is divided into linear regul...
    more
  • Difference between kVA and kw

    Difference between kVA and kw

    Mar , 15 2025
    kVA is the unit of apparent power and kw is the unit of active power. In alternating current, apparent power does not indicate the actual power consumed in the circuit, but rather the maximum power that can be supplied or the maximum active power consumed in an alternating current circuit. In the case of active power, it is the power needed to enable the equipment to work properly, such as the ele...
    more
  • Radio Frequency Interference Filters (RFI)

    Radio Frequency Interference Filters (RFI)

    Apr , 03 2025
    Chapter 1: Application Scenarios of RFI Filters in Industrial Chargers RFI Filter is a key component for solving high-frequency electromagnetic interference (EMI), which is especially indispensable in high power and high frequency equipment such as industrial chargers. Industrial chargers are often faced with complex electromagnetic environments: fast switching of switching power supplies, high-cu...
    more
  • How electrolytic capacitor work for industrial battery charger

    How electrolytic capacitor work for industrial battery charger

    May , 16 2025
    I. What is electrolytic capacitor: 1. Electrolytic capacitor, as the “energy storage heart” of charger power module, bears the key tasks of filtering, voltage stabilization and transient response. Its large-capacity characteristics (up to tens of thousands of μF) can effectively absorb the pulsating current after rectification, reduce output ripple, and ensure that the charging process is stable a...
    more
  • An Overview of HV Substation Equipment — with Integration of High-Current DC Charging Systems

    An Overview of HV Substation Equipment — with Integration of High-Current DC Charging Systems

    May , 24 2025
    Each operating device in a high-voltage substation serves a vital role. Their shapes and sizes vary depending on their location and purpose, but together they ensure safe, stable, and efficient operation of the entire installation. 1. Switchgear: The Functional Core of a Substation Switchgear consists of various components like circuit breakers, disconnectors, earthing switches, and instrument tra...
    more
  • Understanding Instantaneous Load and Charger Capacity Calculation in Substations

    Understanding Instantaneous Load and Charger Capacity Calculation in Substations

    Jun , 07 2025
    In modern substations, accurate power system design requires a clear understanding of instantaneous (transient) loads and how they impact equipment sizing, particularly for battery chargers in DC systems. This article breaks down the concept of transient loads, their implications, and how to properly calculate charger capacity under such conditions. 1. What Is an Instantaneous (Transient) Load? A ...
    more
  • Empowering Telecom with Green Energy: EverExceed Stacked Solar Power System

    Empowering Telecom with Green Energy: EverExceed Stacked Solar Power System

    Sep , 05 2025
    As the demand for 5G networks and data centers continues to rise, telecom operators face mounting challenges in balancing energy reliability and carbon reduction goals. EverExceed’s Telecom Base Station Stacked Solar Power System provides an innovative solution by integrating solar generation with traditional grid power—helping operators achieve stable, efficient, and sustainable energy supply. Sy...
    more
  • Reliable Backup Power Redefined — EverExceed DC Power Supply Panels

    Reliable Backup Power Redefined — EverExceed DC Power Supply Panels

    Sep , 28 2025
    Introduction In today’s power-dependent society, the reliability of power supply systems directly determines the stability of modern infrastructure. Within this context, DC power supply panels—commonly known as DC power supply systems or “DC screens”—play an irreplaceable role as the “last line of defense” in backup power. These intelligent, maintenance-free DC systems have become indispensable in...
    more
  • Soft Start Technology in Thyristor Battery Chargers

    Soft Start Technology in Thyristor Battery Chargers

    Dec , 19 2025
    In modern industrial power systems, industrial battery chargers play a critical role in ensuring stable DC power for control, protection, and backup applications. Their reliability and service life directly affect the continuity of industrial operations. Industrial-grade thyristor (SCR) battery chargers are widely used in metallurgy, chemical plants, mining, substations, and heavy industries due t...
    more
  • Powering the Industrial Lifeline with Uninterrupted Reliability

    Powering the Industrial Lifeline with Uninterrupted Reliability

    Dec , 19 2025
    In modern industrial operations, the smooth operation of production lines, the reliability of power and control systems, and the precise coordination of rail and transportation networks all depend on a critical but often overlooked infrastructure—the DC Uninterruptible Power Supply (DC UPS).   Unlike conventional AC UPS systems designed mainly for IT equipment, DC UPS systems safeguard ...
    more