1-3kVA PL3 RM Series High Frequency Online UPS
MODEL
(Low voltage version)
|
PL3 RM1KS
|
PL3 RM1KL
|
PL3 RM2KS
|
PL3 RM2KL
|
PL3 RM3KS
|
PL3 RM3KL
|
Capacity
|
1kVA/1kW
|
1kVA/1kW
|
2kVA/2kW
|
2kVA/2kW
|
3kVA/3kW
|
3kVA/3kW
|
Phase
|
1 Phase in/1 Phase out
|
INPUT
|
Nominal Voltage
|
100/110/115/120/127VAC (L-N Voltage), L+N+PE
|
Input Voltage Range
|
85~155VAC (L-N Voltage)@100%load; 85~55VAC, linearly derating from 100% to 50% load
|
Input Frequency Range
|
50/60±6Hz
|
Input Power Factor
|
>0.99
|
Input Current Distortion (THDi)
|
<4%
|
Bypass Voltage Range
|
-40%~20% of nominal voltage, adjustable
|
OUTPUT
|
Nominal Votage
|
100/110/115/120/127VAC (L-N Voltage), L+N+PE
|
Voltage Regulation
|
± 1 %
|
Nominal Frequency
|
50/60Hz, adjustable
|
Output Frequency
|
Line Mode:50/60±1/2/3/4/5/6Hz , adjustable ; Battery Mode: 50/60±0.001 Hz
|
Output Power Factor
|
1
|
Output Voltage Distortion (THDu)
|
≤3%@linear load; ≤5%@non-linear load
|
Transfer Time
|
Line mode to Battery mode, 0ms; Inverter to Bypass, 4ms (Synchronized);
Bypass to Inverter, 4ms(Synchronized); ECO to Battery Mode, 6ms (Typical Time)
|
Crest Ratio
|
3:1
|
Overload Capacity
(Line Mode)
|
10 min @ 102%~110% load;
1 min @ 110%~130% load;
10s @130%~150% load;
200 ms @ >150% load
|
Overload Capacity (Battery Mode)
|
1 min @ 102%~110% load;
10s @ 110%~130% load;
3s @130%~150% load;
200 ms @ >150% load
|
Overload Capacity (Bypass Mode)
|
Depending the input breaker (20A)
|
Depending the input breaker (20A)
|
Depending the input breaker (40A)
|
Depending the input breaker (40A)
|
Depending the input breaker (40A)
|
Depending the input breaker (40A)
|
Output Short Circuit Protection
|
Line Mode: Current limitation; Battery Mode: Current limitation; Bypas Mode: Breaker
|
BATTERY
|
Battery Type
|
Sealed Lead Acid Maintanance Free (VRLA)
|
Nominal Voltage
|
24VDC
|
36VDC
|
48VDC
|
72VDC
|
72VDC
|
96VDC
|
Charging Voltage
|
Floating Charge, 2.25V/cell; Boost Charge, 2.35V/cell
|
Battery Number&Capacity
|
2 pcs, 12V/9Ah
|
External
|
4 pcs, 12V/9Ah
|
External
|
8 pcs, 12V/9Ah
|
External
|
Charging Current
|
1A
|
1~12A, adjustable
|
1A
|
1~12A, adjustable
|
1A
|
1~12A, adjustable
|
Charging Mode
|
Two Satges (CC/Floating) or Three Stages (CC/CV/Floating, settable)
|
Typical Recharge Time
|
9 hours recharge to 90%
|
Depending on the capacity of external batteries
|
9 hours recharge to 90%
|
Depending on the capacity of external batteries
|
9 hours recharge to 90%
|
Depending on the capacity of external batteries
|
Battery Protection
|
Battery Leakage<500µA, Over Voltage Protection, Under Voltage Protection, Over Current Protection;
Battery Deep Discharge Protection
|
EFFICIENCY
|
Line Mode
|
93.5% (Max)
|
93.5% (Max)
|
Battery Mode
|
89.5% (Max)
|
90.5% (Max)
|
92.5% (Max)
|
93.5% (Max)
|
92.5% (Max)
|
93.5% (Max)
|
ECO Mode
|
98%
|
INDICATORS
|
LCD Panel
|
UPS status, Battery Level, Load Level, Input/Outpt/Battery Voltage, Fault&Alarm Code
|
Audible Alarm
|
Utility Failure, Battery Voltage Low, Overload, System Fault
|
MANAGEMENT
|
Interface
|
RS232 ,USB, EPO Port, SNMP Card (Optional), Relay Card (Optional)
|
ENVIRONMENT
|
Operating Temperature
|
0~40℃
|
Operating Humidity
|
0~95% RH, non-condensing
|
Storage Temperature
|
-15~60℃ (Battery: 0-40℃)
|
Altitude
|
<1000m, derating 1% per 100m from 1000~ 2000m
|
Noise (1Meter Away)
|
<50dB
|
PHYSICAL
|
Dimension
(W*D*H, unit:mm)
|
440*425*86
|
440*588*86
|
440*470*86
|
440*733*86
|
440*470*86
|
Net Weight (kg)
|
9/11.3
|
4.5
|
19/23.6
|
10
|
25/29.6
|
11
|
Color
|
Black ( RAL9004)
|
STANDARDS
|
Safety
|
IEC 62040-1:2017
|
EMC
|
IEC 62040-2:2018
|
Performance
|
IEC 62040-3:2011
|
Battery
|
IEC 60896-22:2004
|
1-10KVA PL3 RM Series High Frequency Online UPS
MODEL
|
PL3 RM1KS
|
PL3 RM1KL
|
PL3 RM2KS
|
PL3 RM2KL
|
PL3 RM3KS
|
PL3 RM3KL
|
PL3 RM6KL
|
PL3 RM10KL
|
Capacity
|
1kVA/1kW
|
1kVA/1kW
|
2kVA/2kW
|
2kVA/2kW
|
3kVA/3kW
|
3kVA/3kW
|
6kVA/6kW
|
10kVA/10kW
|
Phase
|
1
Phase in/1 Phase out
|
INPUT
|
Nominal Voltage
|
208/220/230/240VAC
(L-N Voltage), L+N+PE
|
Input Voltage Range
|
176~300VAC
(L-N Voltage)@100%load; 176~110VAC, linearly derating from 100% to 50% load
|
Input Frequency Range
|
50/60±6Hz
|
Input Power Factor
|
>0.99
|
Input Current Distortion (THDi)
|
<4%
|
<5%
|
Bypass Voltage Range
|
-40%~20%
of nominal voltage, adjustable
|
OUTPUT
|
Nominal Votage
|
208/220/230/240VAC,
L+N+PE
|
Voltage Regulation
|
± 1
%
|
Nominal Frequency
|
50/60Hz,
adjustable
|
Output Frequency
|
Line
Mode:50/60±1/2/3/4/5/6Hz , adjustable
; Battery Mode: 50/60±0.001 Hz
|
Output Power Factor
|
1
|
Output Voltage Distortion (THDu)
|
≤3%@linear
load; ≤5%@non-linear load
|
≤2%@linear
load; ≤5%@non-linear load
|
Transfer Time
|
Line
mode to Battery mode, 0ms; Inverter to Bypass, 4ms (Synchronized); Bypass to
Inverter,
4ms(Synchronized); ECO to Battery Mode, 6ms (Typical Time)
|
Line
mode to Battery mode, 0ms;
Inverter to Bypass, 0ms (Synchronized);
Bypass to Inverter, 0ms(Synchronized);
ECO to Battery Mode, 2ms (Typical Time)
|
Crest Ratio
|
3:1
|
|
|
Overload Capacity
(Line Mode)
|
30
min @ 102%~110% load;
10 min @ 110%~130% load;
30s @130%~150% load;
200 ms @ >150% load
|
10
min @ 102%~110% load;
1 min @ 110%~130% load;
10s @130%~150% load;
200 ms @ >150% load
|
30
min @
102%~110% load;
10 min @ 110%~130% load;
30s @130%~150% load;
200 ms @ >150% load
|
Overload Capacity (Battery Mode)
|
1 min
@ 102%~110% load;
10s @ 110%~130% load;
3s @130%~150% load;
200 ms @ >150% load
|
10
min @ 102%~110% load;
1 min @ 110%~130% load;
10s @130%~150% load;
200 ms @ >150% load
|
Overload Capacity (Bypass Mode)
|
Depending
the input breaker (10A)
|
Depending
the input breaker (20A)
|
Depending
the input breaker (63A)
|
Output Short Circuit Protection
|
Line
Mode: Current limitation; Battery Mode: Current limitation; Bypass Mode:
Breaker
|
BATTERY
|
Battery Type
|
Sealed
Lead Acid Maintanance Free (VRLA)
|
Nominal Voltage
|
24VDC
|
36VDC
|
48VDC
|
72VDC
|
72VDC
|
96VDC
|
192VDC
|
Charging Voltage
|
Floating
Charge, 2.25V/cell; Boost Charge, 2.35V/cell
|
Battery Number&Capacity
|
2
pcs, 12V/9Ah
|
External
|
4
pcs, 12V/9Ah
|
External
|
8
pcs, 12V/9Ah
|
External
|
External
|
Charging Current
|
1A
|
1~12A,
adjustable
|
1~4A,
adjustable, default 1A
|
1~12A,
adjustable
|
1~4A,
adjustable, default 1A
|
1~12A,
adjustable
|
1~12A,
adjustable
|
Charging Mode
|
Two
Satges (CC/Floating) or Three Stages (CC/CV/Floating, adjustable )
|
Typical Recharge Time
|
Depending
on the capacity of external batteries
|
Battery Protection
|
Battery
Leakage<500µA,Over Voltage Protection,Under Voltage Protection,Over Current
Protection; Battery Deep Discharge Protection
|
EFFICIENCY
|
Line Mode
|
94.5%
(Max)
|
94.5%
(Max)
|
95.5%
(Max)
|
95.5%
(Max)
|
95.5%
(Max)
|
Battery Mode
|
87.5%
(Max)
|
88.5%
(Max)
|
89.5%
(Max)
|
91.5%
(Max)
|
95%
(Max)
|
ECO Mode
|
98%
|
98.5%
|
INDICATORS
|
LCD Panel
|
UPS
status, Battery Level, Load Level, Input/Outpt/Battery Voltage,
Fault&Alarm Code
|
Audible Alarm
|
Utility
Failure, Battery Voltage Low, Overload, System Fault
|
MANAGEMENT
|
Interface
|
RS232
,USB, EPO Port, SNMP Card (Optional), Relay Card (Optional)
|
ENVIRONMENT
|
Operating Temperature
|
0~40
℃
|
Operating Humidity
|
0~95%
RH, non-condensing
|
Storage Temperature
|
-15~60℃
(Battery: 0-40 ℃)
|
Altitude
|
<1000m,
derating 1% per 100m from 1000 ~ 2000m
|
Noise (1Meter Away)
|
<50dB
|
<55dB
|
PHYSICAL
|
Dimension
(W*D*H, unit:mm)
|
440*335*86
|
440*425*86
|
440*570*86
|
440*425*86
|
440*487*86
|
Net Weight (kg)
|
8.6
|
4
|
15.6
|
6.4
|
22.5
|
8.2
|
15
|
17
|
Color
|
Black
( RAL9004)
|
STANDARDS
|
Safety
|
IEC
62040-1:2017
|
EMC
|
IEC
62040-2:2018
|
Performance
|
IEC
62040-3:2011
|
Battery
|
IEC 60896-22:2004
|