EverExceed Inverter & Rectifier
power you applications
 
       
 
EverExceed Industrial establish a long-term partnership with our customers through bring high standard quality control and great customer service for them according to the demand of international market. We create the valuable new products for our customers in the long run
 
 
PV Range Grid-off Industrial Inverters
 
 
Features
● Available in capacities up to 80kVA
● True on-line design
● Simple configuration
● DSP digital control and IGBT technology
● Sinewave Pulse Width Modulation
● Output isolation transformer
● High efficiency
● Output short circuit dual protection design
● Harmonic filtering
● Easier power cable entry
● LCD & LED displays
● Easy readout and menu
 
  Applications
● Photovoltaic
● Solar/Wind Energy
● Telecommunications
● Electric Utility
● Power Plant
 
 
PV Range 48E/110E/220E Single Phase Industrial Inverter General Specifications
Model
48E
110E
220E
Rating Power
2K
3K
5K
6K
10K
15K
20K
25K
30K
40K
Input    
Voltage
48VDC+/-15%
110VDC+/-15%
220VDC+/-15%
Output
Voltage
220VAC±1%
Frequency
50Hz or 60Hz (Battery Supply)
Waveform
Sine wave
Frequency Stability
<+/-0.1%
Crest Ratio
>3:1
Harmonic Distortion
Linear Load THD<3%
Transient ordinal change of dynamic load voltage
<±5% (0-100% jump)
Transient Recovery Time
less than 10ms
Balance Load Voltage
<+/-1%, <+/-5% (non-balance load voltage)
Inverter Efficiency
>85%
Overload capability
120% 1minute
Temperature
-10-50°C
Cooling Style
Temperature control compulsive ventilation
Humidity
0-90% non-condensing
Acoustic Noise
<45dB
<50dB
Protection Function
Overload, Short Circuit, Low-oltage, Over-voltage, Over Temperature
 
Weight
67kgs
78kgs
95kgs
98kgs
152kgs
190kgs
240kgs
310kgs
325kgs
380kgs
Dimensions(LxWxH) mm
340x480x865
440x550x1070
660x900x1382
Input/Output Layout
Terminals
Indicator
Main Power (Green), Inverter (Green), Bypass Output (Orange), Battery Power (Red), Overload (Red), Malfunction (Red)
 
 
PV Range 220T Three Phase Industrial Inverter General Specifications
Model
220T
Rating Power
10K
15K
20K
30K
40K
50K
60K
80K
Input  
Voltage
380VDC±20%
Output
Voltage
380VAC±1%
Frequency
50Hz or 60Hz (Battery Supply)
Waveform
       
Sine wave
Frequency Stability
<+/-0.1%
Crest Ratio
>3:1
Harmonic Distortion
Linear Load THD<3%
Transient ordinal change of dynamic load voltage
<±5% (0-100% jump)
Transient Recovery Time
less than 10ms
Balance Load Voltage
<+/-1%, <+/-5% (non-balance load voltage)
Inverter Efficiency
>90%
Overload capability
125% 10minutes, 150% 1minute
Temperature
-10-50°C
Cooling Style
Temperature control compulsive ventilation
Humidity
0-90% non-condensing
Acoustic Noise
<50dB
<60dB
<68dB
Protection Function
Overload, Short Circuit, Low-oltage, Over-voltage, Over Temperature
 
Weight
128kgs
178kgs
260kgs
340kgs
380kgs
480kgs
510kgs
800kgs
Dimensions(LxWxH) mm
340x480x1065
440x550x1065
900x700x1400
800x900x1432
Input/Output Layout
Terminals
Indicator
Main Power (Green), Inverter (Green), Bypass Output (Orange), Battery Power (Red), Overload (Red), Malfunction (Red)