Uninterruptible Power Supplies
Advanced power protection for various applications
 
       
 
EverExceed Corporation establish a long-term partnership with our customers through bring high standard quality control and great customer service for them according to the demand of international market. We create the valuable new products for our customers in the long run
 
POWERPLUS SERIES ON-LINE DOUBLE CONVERSION MODULAR UPS
 
 
  Catalogue Download
   
Overview
EverExceed EverExceed State-of-the-art PowerPlus series, a multimode abstemious green UPS, based on the true online topology, is modular designed along with large-power, superior quality and is trusted by the entire world. Leading technology tendency, N+X modules, hot-insertion, easily scalable all these combination truly satisfy customer's requirement! EverExcceed PowerPlus series UPS is a true modular, user-upgradeable system. As load increases you can insert up to a total of ten 10 kVA hot-swap plug-in modules. The PowerPlus series can be configured in parallel for N+X redundancy. The characterstics as follows:
● Adopted module parallel connection, PowerPlus series UPS support hot-swap plug-in, support multimode, support distributed logic parallel connection, support touch screen, and so on, al ofl these represent the most advanced technology in the field. Each layer and module is independently installed, efficiently resolve the extension and upgrade of the product, at the same time PwerPlus series provide the simplest , fastest, most reliable and most secure application mode for products, establishing the highest performance to price ratio.
● Adopted the module parallel connection, there are four input and output modes of status can be provided, 3/3, 3/1, 1/1,1/3, can satisfy various power requirements in all field, meet all the purposes and all the kinds of demands.
● Adopted standard size of 2U equipment cabinet, structure is rational, good operable, easy maintenance, fashion shape, can easily be connected to computer, network equipment, and so on.
● Adopted centralized management, concerning the sections which operated frequently by customer, managed in a panel, so greatly improve the stability and the reliability of equipment.

 
             
  Features:
● Multimode
Complete refresh the oneness of phase fixed of UPS's input and output, provide customer the selectable room and convenience , which never provided ever. Power Plaus can be configured in any situation, so as to satisfy the power requirement in all field. According to the input structure, operator can configure four work modes: three phases in three phases out, three phases in single phase out, single phase in single phase out, single phase in three phases out, and can keep the power constant. As the multimode of the products, the customer needn't to consider of how to bought different phase or different power capacity other products.

● Scalable
Use the module parallel design, consist of 1 to 10 rated UPS modules,support hot plug and can be expand as you want. Realize the investor's strategy, a change along with the requirement, satisfy the business growth, so establish the dynamic increase of UPS.Not only satisfy the later period expand along with the requirement, but also reducing customer's forepart cost; When
customer estimate the capacity of UPS, often estimate higher or lower than the real level, modularize UPS can efficiently resolve this sort questions, help user with resolving period investment and construct when the future development direction is not sure or the load isn't sure.

● Applicability
Traditional UPS usually use Stand-alone, hot standby or 1+1 parallel connection. Use Stand-alone easy occur single node failure, and hot standby or 1+1 not only waste the electric power, but also the permission times of wrong is only once.
Modularize UPS use N+X parallel connect, the user can decide the quantity of UPS module according to his load and the power redundancy for secure requirement , so do the customer can gain a higher jump of performance to price ratio and reliability. EverExceed PowerPlus UPS have the ultra capacity of parallel connect, is the leading represent of advanced technology ,its average time of no failure is 1.5 times long than traditional one, average no big failure value is three times long than traditional one, average comeback time is less 0.1 time than traditional one. Its ultra performance shows the time of protecting user's equipment is greatly increased.

● Energy Saving Property
Traditional UPS's highest efficiency is usually less than 90%, there is 10% energy is wasted, EverExceed PowerPlus UPS series' inverting efficiency highly come to above 96%, greatly save the energy for user.

● Environmental Protection
Traditional UPS's harmonic wave factor usually is about 30%; this pollutes the public electric network, in the same time increase the dissipation. EverExceed PowerPlus UPS series apply advanced improving technology ,its input power factor is nearly equal to 1,input harmonic distortion is less 5%,is far less than the similar UPS products, greatly decrease interference of the power and pollution to public electronic network, efficiently reduce the public network's burden and the power dissipation.

● Support Hot-swap plug in
Use the most advanced hot plug technology, modules support plug and play, you need no power off, realize the parallel system's maintenance online, overcome the bypass maintenance's technology problem of traditional UPS, it is very easy to maintenance UPS, in the same time also realize the performance of expand and redundancy of UPS as you want, sufficiently and truly satisfy requirement of users.

● Interaction
Use the inimitable interactive monitor technology, help user quickly and agilely dealing with emergent crisis in real time. Using network communication, you can monitor UPS in a real time mean, avoid your worry.
 
     
 
General Specifications of PowerPlus Series UPS (1)
Model P+10 P+20 P+30 P+40 P+50 P+60 P+70 P+80
Output Capacity(KVA/KW) 10/8 20/16 30/24 40/32 50/40 60/48 70/56 80/64
Input Voltage 3 phase 4 line input:208VAC               1 phase 2 line input:120VAC
Voltage Range Line voltage:90VAC~150VAC                phase voltage:160VAC~270VAC
Frequency Range 60Hz±5Hz
Power Factor ≥0.99
Bypass range 90VAC~150VAC
Output Voltage 3 phase 4 line input:208VAC          1 phase 2 line input:120VAC
Frequency/Range (50Hz±0.01Hz or 60Hz±0.01Hz)/46Hz~54Hz(Tracing)
Voltage Precision 208VAC±2% or 120VAC±2%
Voltage Unbalance ±3%(100% Unbalance load)
Voltage Deviation ≤3°(phase)
Waveform Sine wave
Total Harmonic Distortion ≤2%(linear load),≤5%(nonlinear load)
Power Factor 0.8
Crest Factor 3:1(max)
Range Time Pulse response:±10%(Resistance Load)
Recover Time Pulse response:≤40ms
Overload capacity 103%~110% for 10min,110%~120% for 1min,>120% for 200ms
Battery Connection Mode Positive and negative two groups supply
Per Group 32cells
DC Voltage battery:+212VDC,-212VDC
Alarm voltage alarming when cell voltage less than 10.9V
Protecting Voltage closed when cell voltage less than 10.5V
Charge Current Maximum of single module≥10A
Intelligent management Record function:auto-float-charging,average charge conversion and battery discharge
System Instructions Efficiency ≥98%
Transfer Time 0ms
Display Mode LCD+Touch-screen+LED
Audible Noise ≤50dB(full load) at 1meter
Lack /over voltage Protection:exceed 120Vac±20%.close output automatically and sent out sound-light alarm
Communications interface RS232/422/485
Safety requirement and EMC Meet the requirement of GB7260.2
Temperature (Operating):-20℃~+40℃     (No battery Storage):-25℃~+55℃
Relative Humidity ≤93%(40℃±2℃,noncondensing)
Physical Dimensions(W×D×H)mm 700×600
×708
700×600
×802
700×600
×896
700×600
×990
700×600
×1084
700×600
×1178
700×600
×1272
700×600
×1366
Including Module Amount 1 2 3 4 5 6 7 8
Weight(kg) 65 80 95 110 125 140 155 170
Remark    Product specifications are subject to change without further notice.
 
     
 
General Specifications of PowerPlus Series UPS (2)
Model P+90 P+100 P+110 P+120 P+140 P+160 P+180 P+200
Output Capacity(KVA/KW) 90/72 100/80 110/88 120/96 140/112 160/128 180/144 200/160
Input Voltage 3 phase 4 line input: 208VAC      1 phase 2 line input: 120VAC
Voltage Range Line voltage:90VAC~150VAC  or  phase voltage:160VAC~270VAC
Frequency Range 60Hz±5Hz
Power Factor ≥0.99
Bypass range 90VAC~150VAC
Output Voltage 3 phase 4 line input: 208VAC      1 phase 2 line input: 120VAC
Frequency/Range (50Hz±0.01Hz or 60Hz±0.01Hz)/46Hz~54Hz(Tracing)
Voltage Precision 208VAC±2% or 120VAC±2%
Voltage Unbalance ±3%(100% Unbalance load)
Voltage Deviation ≤3°(phase)
Waveform Sine wave
Total Harmonic Distortion ≤2%(linear load),≤5%(nonlinear load)
Power Factor 0.8
Crest Factor 3:1(max)
Range Time Pulse response:±10%(Resistance Load)
Recover Time Pulse response:≤40ms
Overload capacity 103%~110% for 10min,110%~120% for 1min,>120% for 200ms
Battery Connection Mode Positive and negative two groups supply
Per Group 32cells
DC Voltage battery:+212VDC,-212VDC
Alarm voltage alarming when cell voltage less than 10.9V
Protecting Voltage closed when cell voltage less than 10.5V
Charge Current Maximum of single module≥10A
Intelligent management Record function:auto-float-charging,average charge conversion and battery discharge
System Instructions Efficiency ≥98%
Transfer Time 0ms
Display Mode LCD+Touch-screen+LED
Audible Noise ≤50dB(full load) at 1meter
Lack /over voltage Protection:exceed 120VAC±20%.close output automatically and sent out sound-light alarm
Communications interface RS232/422/485
Safety requirement and EMC Meet the requirement of GB7260.2
Temperature (Operating):-20℃~+40℃   (No battery Storage):-25℃~+55℃
Relative Humidity ≤93%(40℃±2℃,noncondensing)
Physical Dimensions(W×D×H)mm 700×600
×1460
700×600
×1552
 800×600
×1646
800×600
×2000
800×1220
×1800
800×1220
×1800
800×1220
×1800
800×1220
×1800
Including Module Amount 9 10 11 12 14 16 18 20
Weight(kg) 185 200 215 230 260 290 320 350