Uninterruptible Power Supplies
Advanced power protection for various applications
 
       
 
EverExceed Corporation establish a long-term partnership with our customers through bring high standard quality control and great customer service for them according to the demand of international market. We create the valuable new products for our customers in the long run
 
PowerLead Series True On-line Double Conversion UPS
 
 
1-10KVA UPS 120V/60Hz Series 1-20KVA UPS 220V/60Hz Series
1-5KVA for Rack Mount    
Overview
EverExceed PowerLead true on-line UPS are designed to protect against a wide variety of potential power problems including spikes, surges, noise, sags, over and under voltage conditions, waveform distortion and extended brownouts, as well as blackouts...even difficult-to-track harmonics and dangerous frequency variations which are common to a standby generator. It provides superior communication capability via EverExceed hot-swappable SNMP cards. PowerLead allows to be treated as a fully-interactive network node by your network management software.
 
 
 
  Catalogue Download
   
 

Feature:
● True on-line double conversion technology with advanced microprocessor control
● Wide input voltage range
● Zero transfer time
● Protection against all types of power problems
● Self test on start of the UPS
● Site wiring fault warning
● On-battery power-on function
● Smart RS232 communication interface or SNMP remote control
● Intelligent slot available
● Maintenance free VRLA battery
● Generator compatible

  Ideal Applications:
● Office telecommunications systems
● Voicemail and E-Mail servers
● LAN and WAN servers
● Clustered network equipment: hubs, routers, bridges
● Remote telecommunications units
● Test and diagnostic equipment
● Engineering network servers
● Factory floor protection of microprocessor-controlled equipment
 
 
 
 
General Specifications Of PowerLead Rack-Mount
Model PL1KRM PL2KRM PL3KRM PL5KRM
Power (VA / Watts) 1000VA / 700W 2000VA / 1400W 3000VA / 2100W 5000VA / 3500W
Input Phase Single Phase
Input Voltage Range 60-140VAC or 176-276VAC
Voltage 100V/110V/115V/120V/127V or 220V
Frequency 50Hz/60Hz ± 7%
Power Factor 0.97
Connections or Cord/Plug Type (10 ft) NEMA 5-15P (10 ft) NEMA 5-20P (10 ft) NEMA L5-30P
Output Voltage 100VAC/110VAC/115VAC/120VAC/127VAC±3% or 220VAC±3%
Output Waveform  Sinewave
Receptacles (b=Battery, s=Surge) (6) NEMA 5-15R (6) NEMA 5-20R T-Slot (6) NEMA 5-20R T-Slot (1) L5-30R (12 in)
Frequency 50Hz ± 0.5%(Input frequency synchronization in normal frequency; If input frequnecy over standrad or on electronic frame, the deviation of output frequnecy (relative rated value) is ± 0.5%)
Power Factor hysteresis 0.7
Total Harmonic Distortion THD ≤ 3% (full linear load)
Overload Capability  > 130% for 2s
 > 105% for 30s
Crest Factor 3:1 (max)
UPS Technology On-Line
Transfer Time 0ms; bypass/inverter transformation: 2.5ms, Max: 4ms
Battery Type EverExceed high performance maintenance free valve regulated lead acid battery (VRLA)
Voltage 36V(3 batteries 12V) 96V(8 batteries 12V)
Floating Charge Voltage 41.3V 110V
   Cut Off Voltage 33V 87V
environ-ment Operating Temperature 0~40℃
Storage Temperature -15~40℃
Relative Temperature 0~95℃ no water drop
Elevation 3000m
Sound Emission/Audible Noise < 50dB at 1 meter
Dimensions (WxDxH) (mm) 160×405×220 212×300×455
Weight Net Weight(KG) 11.5 22 23 25
Explanation long backup/
standard
long backup/
standard
long backup/
standard
long backup/
standard
    Computer Interface 9Pin D TYPE Connector
Remark Product specifications are subject to change without further notice.