Advanced power protection for various applications
EverExceed Corporation establish a long-term partnership with our customers through bring high standard quality control and great customer service for them according
to the demand of international market. We create the valuable new products for our
customers in the long run
PowerLead2 Series True On-line Double Conversion UPS
Overview: EverExceed PowerLead2 true on-line UPS are designed to protect against a wide variety of potential power problems including spikes, surges, noise, sags, over and under voltage conditions, waveform distortion and extended brownouts, as well as blackouts...even difficult-to-track harmonics and dangerous frequency variations which are common to a tandby generator. It provides superior communication capability via EverExceed hot-swappable SNMP cards. PowerLead2 allows to be treated as a fully-interactive network node by your network management software.
Feature: ● Paralleling up to 4 units ● True online double conversion technology ● Smart communication port ● IGBT PFC technology ● Wide input range ● Zero transfer time ● Compete protection function ● LCD/LED display ● Cold start function
Ideal Applications: ● Office telecommunications systems ● Voicemail and E-Mail servers ● LAN and WAN servers ● Clustered network equipment: hubs, routers, bridges ● Remote telecommunications units ● Test and diagnostic equipment ● Engineering network servers ● Factory floor protection of microprocessor-controlled equipment
Technical Parameter:
Model
PL2 6K
PL2 6KS
PL2 10K
PL2 10KS
3PL2 10KS
3PL2 15KS
3PL2 20KS
Capacity
6KVA/4800W
10KVA/8000W
10KVA/7000W
15KVA/10500W
20KVA/14000W
Input
Voltage
115Vac~300Vac
304Vac~478Vac
Phase
1P2W + G
3P4W + G
Frequency
50Hz(60Hz)±5%
50Hz(60Hz)±5%
COSΦ
According EN60555-2(≥0.95)
According EN60555-2(≥0.95)
Output
Voltage
220Vac ±1%
220Vac (230Vac)±3%
220Vac (230Vac)±2%
Frequency
50Hz±0.2HZ(BATTERY MODE)
50Hz±5%
COSΦ
0.8(lag)
0.7(lag)
Waveform
Sine wave
Sine wave
WaveForm distortion
Linear load<3%
Linear load<3%
Linear load<4%
Non linear load<6%
Non linear load<6%
Non linear load<5%
Overload protection
>125%→1 MIN >150%→10ms
>130%→200ms >150%→10ms
Transfer time
0ms
0ms
Battery
Sealed lead acid maintenance-free battery
Sealed lead acid maintenance-free battery
External battery voltage
12V7AH*16PCS
192Vdc
12V7AH*16PCS
192Vdc
240VDC
Ambient
Temperature
0 ~ 43oC
0 ~ 43oC
Humidity
0 ~ 95%
0 ~ 95%
Communication
9Pin D type connector (RS232) or intelligent slot for SNMP adaptor(optional)