Uninterruptible Power Supplies
Advanced power protection for various applications
 
       
 
EverExceed Corporation establish a long-term partnership with our customers through bring high standard quality control and great customer service for them according to the demand of international market. We create the valuable new products for our customers in the long run
 
PowerAurora Line-interactive UPS
  Overview
EverExceed PowerAurora series UPS is a very competitive product featuring for low cost and high performance. It safeguards your computers and other sensitive electronics from the damage of outages, surges and other anomalies present on the mains supply. It also provides sufficient backup power to work through short and medium length outages. Its early warning function provides ample time for you to perform an orderly shutdown of your computers during long-term outages.
 
 
  Catalogue Download        
 

Feature:
Microprocessor Control for High Reliability
PowerAurora series UPS applies microprocessor controller for managing the power components. The technoloy highly raises the reliable and stable performance.

Boost and Buck AVR to Stabilize Input Voltage
PowerAurora series UPS equipped with boost and buck AVR feature for providing extraordinary stable voltage. This provides extra protection in the area where the AC input voltage is constantly unstable.

Green Power Function for Effecient Energy Saving
PowerAurora series UPS meets the highest standard for energy saving. When in battery mode and the load can hardly be detected, the system will cease releasing power for energy saving.

Best Cost Performance Balance Design
PowerAurora series UPS adopts advanced new structure for lowering the manufacturing cost but still maintains excellent performance.

Built-in DC Start Function
PowerAurora series UPS can start up without AC power supply.

Auto Restart Function
When AC input power is back on line, the UPS can automatically start without manual setup.

Overload Protection
According to different grade of overload conditions, alert or shut down action will be peformed for preventing further damage to the UPS.

 
     
 
Specifications of PowerAurora Series UPS (1)
Model Aurora500 Aurora600 Aurora650 Aurora700 Aurora800 Aurora850 Aurora900
Power Rating(VA/W) 500/300 600/360 650/390 700/420 800/480 850/510 900/540
Input Phase Single-phase +N
Voltage 110/120VAC or 220/230/240VAC±25%
Frequency 50/60Hz±6%
Output Voltage 110/120VAC or 220/230/240VAC±10%
Frequency AC Mode: Track the Utility      Battery Mode:50/60Hz±0.5Hz
Waveform Sine Wave(Mains)        Modified Sine Wave(Battery)
Crest Factor 3:1(Max.)
Overload capacity ≤120% for 1 minute; ≥120% for 10 seconds
Battery Type VRLA Maintenance-Free Battery
DC Voltage 12VDC 24VDC
Configuration 1×7.2Ah/12V 2×7.2Ah/12V
Charge Current 35mA~1.2A
Backup Time (Full Load)≥3min
System Instructions Short Circuit Protection AC Mode: Fuse     Battery Mode:Shutdown immediately and switch to Fault Mode
Transfer Time 4ms (max.) 
Surge Protection 320 Joules
AVR Provided
Communication Interface RS232/RJ11/RJ45/USB(optional)
Temperature (Operating): 0~40℃    (Storage): -25℃~55℃
Relative Humidity 0~90% noncondensing
Audible Noise ≤45dB at 1 meter 
Elevation ≤1500m
Physical Dimension(W×D×H)mm 146×95×313 196×120×385
Packing Dimension(W×D×H)mm 276×376×463 356×465×255
Net Weight(kg) 5.8 6.2 6.2 13.6
Gross Weight(kg) 6 6.4 6.4 14.4
 
     
 
Specifications of PowerAurora Series UPS (2)
Model Aurora1000 Aurora1200 Aurora1500 Aurora2000 Aurora2200 Aurora2500 Aurora3000
Power Rating(VA/W) 1000/600 1200/720 1500/900 2000/1200 2200/1320 2500/1500 3000/1800
Input Phase Single-phase +N
Voltage 110/120VAC or 220/230/240VAC±25%
Frequency 50/60Hz±6%
Output Voltage 110/120VAC or 220/230/240VAC±10%
Frequency AC Mode: Track the Utility      Battery Mode:50/60Hz±0.5Hz
Waveform Sine Wave(Mains)        Modified Sine Wave(Battery)
Crest Factor 3:1(Max.)
Overload capacity ≤120% for 1 minute; ≥120% for 10 seconds
Battery Type VRLA Maintenance-Free Battery
DC Voltage 24VDC 36VDC
Configuration 2×7.2Ah/12V 3×7.2Ah/12V 3×8Ah/12V 3×9Ah/12V
Charge Current 35mA~1.2A
Backup Time (Full Load)≥3min
System Instructions Short Circuit Protection AC Mode: Fuse     Battery Mode:Shutdown immediately and switch to Fault Mode
Transfer Time 4ms (max.) 
Surge Protection 320 Joules
AVR Provided
Communication Interface RS232/RJ11/RJ45/USB(optional)
Temperature (Operating): 0~40℃    (Storage): -25℃~55℃
Relative Humidity 0~90% noncondensing
Audible Noise ≤45dB at 1 meter 
Elevation ≤1500m
Physical Dimension(W×D×H)mm 196×120×385 125×400×220 192×460×340
Packing Dimension(W×D×H)mm 356×465×255 180×450×295 345×530×475
Net Weight(kg) 14.6 18.5 23 25
Gross Weight(kg) 15.6 20 24.5 26.7