EverExceed Industrial Battery World
Premium quality for uninterrupted communications
 
       
 
EverExceed Technology establish a long-term partnership with our customers through bring high standard quality control and great customer service for them according to the demand of international market. We create the valuable new products for our customers in the long run
 
 
EverExceed Tubular OPzV Range Gel
 

EverExceed tubular plate OPzV Range gelled, maintenance free sealed valve regulated lead acid rechargeable batteries offer their superior performance and reliability in both controlled and harsh uncontrolled environments. EverExceed state-of-the-art manufacturing facilities with wealthy experience ensure it's tubular OPzV gelled batteries reliable performance, safety, outstanding battery life and value. Each cell is 100% factory tested. EverExceed tubular OPzV batteries can be used in float or deep cycle (1500 x 80%)service and have a design life of 20 years at 20°C. EverExceed tubular OPzV batteries can be stored up to 2 years at 20°C without fresh charging.

 
Specification
● Positive electrode: Tubular Plate with     antiminy-free special alloy
● Negative electrode: Flat Grid plate
● Electrolyte: Suspended Thixotropic Gel
● Container & Cover SAN Optional V-0
● Separator: Microporous plastic
● Float Voltage: 2.23 VPC +/- 1% at 20 C
   Max. Charge Voltage: 2.40 VPC at 20 C
● Safety Valve: 1-3 PSI Self-Resealing
● Terminals: Integral Copper Insert
● Interconnects: Insulated cables

 
20 years design life
Tubular plate
Single cell
Nominal capacity:
200 - 3000Ah
 
 
deep discharge recovery
Maintenance free
Recycleable
Valve regulated lead-acid
 
 
General Specifications
Model No.
C10 Ah 1.80
C5 Ah 1.75
C3 Ah 1.75
C1 Ah 1.65
Ri (1) m W
lk (2) A
Outline Dimensions (mm/inch)

Approx.

Weight (kg)

Lenght
Width
Height(h2)
Height(h1)
2V 4 OPzV 200
210
195
174
125
0.94 2235 105 208 398 360 20
2V 5 OPzV 250
260
245
219
156
0.78 2706 126 208 398 360 23
2V 6 OPzV 300
310
290
261
187
0.60 3414 147 208 398 360 27
2V 5 OPzV 350
370
360
315
224
0.61 3418 126 208 513 475 30
2V 6 OPzV 420
450
430
378
268
0.49 4220 147 208 513 475 35
2V 7 OPzV 490
520
505
441
313
0.51 4096 168 208 513 475 40
2V 6 OPzV 600
660
590
504
356
0.44 4743 147 208 688 650 48
2V 8 OPzV 800
820
785
669
494
0.30 6818 212 193 688 650 67
2V 10 OPzV 1000
1030
985
846
611
0.25 8200 212 235 688 650 80
2V 12 OPzV 1200
1230
1185
1026
726
0.21 9840 212 277 688 650 94
2V 12 OPzV 1500
1550
1470
1221
852
0.19 10500 212 277 838 800 118
2V 16 OPzV 2000
2070
1955
1629
1136
0.15 14000 215 400 815 775 160
2V 20 OPzV 2500
2580
2410
2004
1491
0.12 17500 215 490 815 775 200
2V 24 OPzV 3000
3090
2895
2406
1789
0.10 21000 215 580 815 775 240
(1),(2)internal resistance and short - circuit - current from IEC 896-1
   
4 OPzV 100 up to 6 OPzV 600
6 OPzV 2000
20 OPzV 2500 up to 24 OPzV 3000
   
Design
positive electrode tubular - plate with a woven polyester gauntlet and solid grids in a corrosion- resistant PbCaSn - alloy
negative electrode grid - plate in a PbCaSn alloy with long - life expander material 
separation microporous separator
elektrolyte sulphuric acid with a density of 1,24 kg/l, fixed as GEL by fumed silica
container high impact, halogen-free SAN (Styrol-Acryl-Nitril), grey coloured, UL rating 94HB
lid high impact, halogen-free SAN (Styrol-Acryl-Nitril), grey coloured, UL rating 94HB
valve valve with flame arrestor
opening pressure approx. 100 mbar,
closing pressure approx. 50 mbar
pole - bushing 100% gas- and electrolyte-tight, sliding-pole
kind of pole M10 brass insertion
connectors flexible insulated copper cables, with cross-section of
35, 50, 70 or 95 mm²
kind of protection IP 25 regarding DIN 40050, touch protected according VBG 4
Charging
IU - characteristic Imax without limitation
U = 2,23 to 2,25V/cell +- 1%, between 10°C and 45°C
D U/D T = -0,004 V/K below 10°C in the monthly average
boost charge U = 2,35 to 2,40V/cell, time limited
charging time up to 90% 6h with 1,5*I10 initial current, 2.23 V/cell, 50% C10 discharged
Discharge characteristics
reference temperature 20°C
initial capacity 100%
depth of discharge (DOD) normally up to 80%
deep discharges  more than 80% DOD or discharges beyond final discharge
voltages (dependent on discharge current) have to be avoided
Maintenance
every 6 months  check battery voltage, pilot cell voltage, temperature
every 12 months  record battery and cell voltages and temperatures
Operational data
operational life > 15 years at 20°C
>7,5 years at 30°C
>4 years at 40°C
maintenance-free no topping-up water during operational life
IEC 896-2 cykles 1200
self-discharge app. 2% per month at 20°C
recovery after deep discharge very good
operational temperature -20°C to 45°C
recommended 10°C to 30°C
short-time 45°C to55°C
ventilation requirement 25% (f1=0,5 x f2=0,5)due to VDE 0510 part 2
standard DIN 40 742 part 1
tests according IEC 896-2,
safety standard VDE 0510, part 2
transport no dangerous goods during air-, sea- and land transport