EverExceed Corporation establish a long-term partnership with our customers through bring high standard quality control and great customer service for them according
to the demand of international market. We create the valuable new products for our
customers in the long run
This device combines solar charge controller, inverter. The front panel could display the voltage of battery, charging current from solar panel to battery and voltage of AC output from Inverter. It is more convenient for use, more stable for performance and more beautiful for appearance.
Features ●Wide input voltage range
●Built in charge controller and inverter
●Intelligent charge management
●Fault Indication Function
●Perfect protections
Small Capacity Model
ETr Series (PWM) Hybrid Inverter With Controller General Specifications(1)
model specification
ETr100A12V12
ETr150A10V12
ETr300A10V12
ETr300A12V12
ETr500A10V12
ETr500A10V24
DC input from solar panel
≤25V
≤25V
≤25V
≤25V
≤25V
≤50V
Output current from solar panel
≤12A
≤10A
≤10A
≤12A
≤10A
≤10A
Battery Input voltage Range(VDC)
10 to 15VDC
10 to 15VDC
10 to 15VDC
10 to 15VDC
10 to 15VDC
21 to 30VDC
Power of Inverter
100W
150W
300W
300W
500W
500W
DC voltage
12VDC
12VDC
12VDC
12VDC
12VDC
24VDC
Voltage of Output
220VAC+/-5%
THD
≤2%
Efficiency
≥85%
Output frequency
50/60Hz±1%
Overload ability
≤200%
Protection
overload,input overload protection,battery low voltage and short circuit
Tempreature of working condition
-5℃ to 50℃
ETr Series (PWM) Hybrid Inverter With Controller General Specifications(2)
model specification
ETr500A12V12
ETr500A10V24
ETr500A20V24
ETr600A24V12
ETr1000A12V12
ETr1000A12V24
DC input from solar panel
≤25V
≤50V
≤50V
≤50V
≤25V
≤50V
Output current from solar panel
≤12A
≤10A
≤20A
≤24A
≤12A
≤12A
Battery Input voltage Range(VDC)
10 to 15VDC
21 to 30VDC
21 to 30VDC
10 to 15VDC
10 to 15VDC
21 to 30VDC
Power of Inverter
500W
500W
500W
600W
1000W
1000W
DC voltage
12VDC
24VDC
24VDC
12VDC
12VDC
24VDC
Voltage of Output
220VAC+/-5%
THD
≤2%
Efficiency
≥85%
Output frequency
50/60Hz±1%
Overload ability
≤200%
Protection
overload,input overload protection,battery low voltage and short circuit
Tempreature of working condition
-5℃ to 50℃
ETr Series (PWM) Hybrid Inverter With Controller General Specifications(3)
model specification
ETr1000A20V24
ETr1000A45V24
ETr2000A45V24
ETr3000A40V48
ETr3000A110V24
ETr3000A110V48
DC input from solar panel
≤50V
≤50V
≤50V
≤50V
≤50V
≤100V
Output current from solar panel
≤20A
≤45A
≤45A
≤40A
≤110A
≤110A
Battery Input voltage Range(VDC)
21 to 30VDC
21 to 30VDC
21 to 30VDC
21 to 30VDC
21 to 30VDC
48VDC
Power of Inverter
1000W
1000W
2000W
3000W
3000W
3000W
DC voltage
24VDC
24VDC
24VDC
48VDC
24VDC
48VDC
Voltage of Output
220VAC+/-5%
THD
≤2%
Efficiency
≥85%
Output frequency
50/60Hz±1%
Overload ability
≤200%
Protection
overload,input overload protection,battery low voltage and short circuit