Power Your Applications
 
       
 

EverExceed Corporation establish a long-term partnership with our customers through bring high standard quality control and great customer service for them according to the demand of international market. We create the valuable new products for our customers in the long run





 
     
 
20AH DC Power Supply System

Instructions
Catalogue Download

1.After installing the battery, turn the main power switch, battery indicator light indicates normal, connected solar panels, the red charging indicator light, solar battery charger for the normal (first use, please charge it continuously for three days before discharge).
2.If the battery voltage is sufficient, the load-discharge light is on, the DC power output port out.
3.The anti-backflow device has circuitry keep the solar panels directly on a host, in orderto ensure access to more power. If the prolonged use of batteries may cause battery voltage protection (load indicator light turns off, no output load, a battery indicator light), use solar panels when there is sunlight 10 hours of continuous charge, and then reboot the device to restore electricity or otherautomatically restore its power.
4.If the battery voltage greater than 14V, the charging indicator starts flashing, the battery is fully into the floating state.
5.AC/DC charging port for emergency mouth, not in the case of solar power adapter can be used to charge the battery,charging current shall not exceed 2A.

 

 20AH DC Power Supply System
Parametesr Value
Rated charing current 2A
Rated discharge current 2A
Rated Operating voltage 12V
Solar panel voltage <=25V
Float voltage 14V
Undervoltage protection 10.5V
Voltage recovery 11.5V
Load loss <=8mA
USB interface current <=500mA
Operating temperature -10°C~50°C
Storage temperature -15°C~40°C
Humidity <=90%, No Condensation